Electrical Requirements
■U.S. and Canada:
Other countries:
■Outlet must not be controlled by an on/off switch
■Grounding to comply with Underwriters Laboratories (UL) 1459:
A.An insulated grounding conductor that is not smaller in size and equivalent in insulation material and thickness to the grounded and ungrounded branch circuit supply conductors, except that it is green with or without one or more yellow stripes, is to be installed as part of the circuit that supplies the product or system.
B.The grounding conductor mentioned in item A is to be connected to ground at the service equipment.
C.The
Requirements for Out-of-Building Extensions
Installation of a telephone or other standard (tip/ring) device in another building requires the following
■System phone: two Lucent Technologies IROB protectors
■Standard device: one Lucent Technologies IROB protector plus carbon block protection
Wiring | ■ | System phones: Lucent Technologies SYSTIMAX® Bulk Nonplenum (DIW) cable, Lucent | |
|
| Technologies SYSTIMAX Bulk Plenum (HALAR/HALAR) cable, or at least | |
|
| (“home run” not “loop”) | |
| ■ | Other standard telecommunications equipment | |
|
| machines, etc.): | |
|
| recommended) | |
| ■ | Bridging adapter: Lucent Technologies 267F2 | |
| ■ | Range: 1,000 feet (305 meters) for system phones; 3,000 feet (915 meters) for standard devices | |
|
|
| |
Safety | ■ | U.S.: Meets UL 1459 Issue 2 | |
Requirements | ■ | Canada: Meets CSA C22.2, 225 | |
| ■ | All other countries: Meets IEC950 Second Edition and EN60950 Second Edition | |
|
|
|
|
Government | ■ | U.S.: | FCC Part 68 |
Approvals and |
|
| FCC registration number (U.S.): KF: AS5 |
Local Phone |
|
| MF: refer to FCC Reg. No. on side of carrier |
Company |
|
| FCC Part 15 Class A |
Information |
|
| REN (outside line jack): 0.9A per line jack |
|
|
| Jack type: RJ11C |
|
|
| Loop start lines |
| ■ | Canada: | IC CP01, Issue 7 |
|
|
| IC registration number (Canada): 230 3756A |
|
|
| IC CS03, Issues 6 & 7 |
|
|
| Load Number = 7 |
|
|
| Loop start lines |