Electrical Requirements

U.S. and Canada: 90–130 VAC, 50–60 Hz, 3-prong outlet separate ground, separately fused at 15 Amps

Other countries: 90–264 VAC, fused at 10 Amps

Outlet must not be controlled by an on/off switch

Grounding to comply with Underwriters Laboratories (UL) 1459:

A.An insulated grounding conductor that is not smaller in size and equivalent in insulation material and thickness to the grounded and ungrounded branch circuit supply conductors, except that it is green with or without one or more yellow stripes, is to be installed as part of the circuit that supplies the product or system.

B.The grounding conductor mentioned in item A is to be connected to ground at the service equipment.

C.The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type, and the grounding conductors serving these receptacles are to be connected to earth ground at the service equipment.

Requirements for Out-of-Building Extensions

Installation of a telephone or other standard (tip/ring) device in another building requires the following In-Range Out-of-Building (IROB) protectors to protect the control unit and device from electrical surges:

System phone: two Lucent Technologies IROB protectors

Standard device: one Lucent Technologies IROB protector plus carbon block protection

Wiring

System phones: Lucent Technologies SYSTIMAX® Bulk Nonplenum (DIW) cable, Lucent

 

 

Technologies SYSTIMAX Bulk Plenum (HALAR/HALAR) cable, or at least 2-pair (4-wire) star

 

 

(“home run” not “loop”)

 

Other standard telecommunications equipment (single-line phones, fax machines, answering

 

 

machines, etc.): 1-pair (2-wire) mounting cords (Lucent Technologies D2R mounting cords

 

 

recommended)

 

Bridging adapter: Lucent Technologies 267F2

 

Range: 1,000 feet (305 meters) for system phones; 3,000 feet (915 meters) for standard devices

 

 

 

Safety

U.S.: Meets UL 1459 Issue 2

Requirements

Canada: Meets CSA C22.2, 225

 

All other countries: Meets IEC950 Second Edition and EN60950 Second Edition

 

 

 

 

Government

U.S.:

FCC Part 68

Approvals and

 

 

FCC registration number (U.S.): KF: AS5 USA-61630-KF-E

Local Phone

 

 

MF: refer to FCC Reg. No. on side of carrier

Company

 

 

FCC Part 15 Class A

Information

 

 

REN (outside line jack): 0.9A per line jack

 

 

 

Jack type: RJ11C

 

 

 

Loop start lines

 

Canada:

IC CP01, Issue 7

 

 

 

IC registration number (Canada): 230 3756A

 

 

 

IC CS03, Issues 6 & 7

 

 

 

Load Number = 7

 

 

 

Loop start lines

Specifications A-3