State Industries 196114-000 Water Temperature is TOO HOT, GAS Smellat the Heater

Page 14

4.If the heater was installed when incoming water temperatures were warm, colder incoming temperatures will create the effect of less hot water.

5.The thermostat water temperature adjusting dial may be set too low.

6.If you cannot determine the cause of the problems, contact your dealer.

WATER TEMPERATURE IS TOO HOT

1.The thermostat water temperature adjusting dial may be set too high.

2.If lowering control setting does not reduce the water temperature contact your dealer.

GAS SMELLAT THE HEATER

1.Close the main Shut-off valve in the gas supply pipe near the heater, see fig. 4 on page 8. The thermostat includes a gas control (top knob) which can also be closed.

2.Call your gas company.

WATER LEAKAGE IS SUSPECTED

1.Check to see if the heater drain valve is tightly closed.

2.The apparent leakage might be condensation. In warm or humid locations, condensation can accumulate and run from within the heater or its piping.

When a water heater is first installed and filled, the bottom of the tank might condense water. The water accumulation, if excessive, can drip into the floor shield. Also, during normal operation there may be occasions when large

quantities of water are drawn, chilling the tank bottom. This too can result in condensation.

Condensation, appearing in the vent pipe (water dripping from draft diverter) during heater operation is evidence of poor vent action. Possible causes are too long a vent pipe or improper chimney operation.

3.If the leakage is from the temperature and pressure relief valve or its discharge pipe, it may represent a normal condition. However, see RELIEF VALVE section on page 12. DO NOT PLUG THE TEMPERATURE AND PRESSURE RELIEF VALVE. Also, the leakage could be due to unusually high water pressures or temperatures in the system, or to a faulty relief valve. Your dealer or a qualified service technician should be called to determine the cause of the problem and to correct it.

4.If you cannot identify or correct the source of water leakage:

Close the main Shut-off valve in the gas supply pipe at the heater. See fig. 4, page 8.

Close the valve which feeds water to the cold water inlet at the top of the heater.

Contact your dealer.

WATER HEATER MAKES SOUNDS

1.Occasional excessive condensation, as explained under LEAKAGE, can cause a sizzling sound as the moisture is vaporized by the gas flame. This is a normal sound and may be disregarded.

2.Sediment and water scale accumulations may cause rumbling noises. Contact your dealer for details of flushing the heater.

3.If you cannot identify or remedy the condition, contact your dealer.

14

Image 14
Contents Installation Operation Service Maintenance Limited Warranty Commercial GAS Water HeaterDimensions Recovery CapacitiesTable of Contents Insulation Blankets Installation InstructionsHigh Altitude Installations Required AbilityAIR Requirements ClearancesHard Water Combination Water Potable Heating and Space HeatingSystem Connections VentingRelief Valve DrafthoodSingle Temperature GAS PipingGAS Meter Size Natural GAS only PurgingGAS Pressure Regulator Manifold Pressure Setting OperationFor Your Safety Read Before Lighting Checking Venting Temperature RegulationHigh Temperature Limit Switch Checking GAS Input Service InformationPilot and Main Burner Pilot and Main BurnerChecklist Water Leakage is Suspected Water Temperature is TOO HOTGAS Smellat the Heater Water Heater Makes Sounds

196114-000 specifications

State Industries 196114-000 is a prominent model in the realm of water heaters, designed to meet the diverse needs of modern households and commercial establishments. Renowned for its reliability and efficiency, this unit embodies advanced technologies that ensure optimal performance, durability, and energy savings.

One of the primary features of the 196114-000 is its high-capacity water tank, which is constructed from robust materials that resist corrosion and wear. This not only extends the lifespan of the unit but also ensures that hot water is readily available for various applications, whether it's for cooking, cleaning, or bathing. The tank's insulation aids in maintaining water temperature, reducing energy consumption and costs over time.

In terms of technology, the State Industries 196114-000 incorporates state-of-the-art heating elements that provide rapid heating of water. These elements are designed for efficiency, which translates into faster recovery rates and consistent water temperature. Additionally, the system employs smart control mechanisms that monitor water usage and adjust heating cycles accordingly, enhancing energy efficiency without compromising performance.

Safety features are another critical aspect of the 196114-000. It includes automatic shut-off functionalities, which protect against overheating and pressure build-up. This ensures not only the longevity of the unit but also safeguards users from potential hazards associated with malfunctioning water heaters.

The design of the 196114-000 is user-friendly, featuring an intuitive control panel that allows for easy temperature adjustments and monitoring. Maintenance is also simplified, with accessible components that make servicing straightforward and wear part replacement feasible without specialized tools.

Moreover, the compatibility of the State Industries 196114-000 with various installation configurations makes it a versatile choice for both residential and commercial applications. Its compact size allows for floor or wall mounting, catering to spaces with limited square footage.

In conclusion, the State Industries 196114-000 stands out in the competitive market of water heaters due to its blend of efficiency, safety, and advanced technology. Whether you're looking to upgrade your current system or install a new unit, this model promises reliable hot water supply and cost-effective operation, making it a trusted choice for countless users.