Graco 220667, 220666, 237012, 220663 Troubleshooting, Symptom Probable Cause Test Procedure Remedy

Page 12

Troubleshooting

Relieve the pressure, and check all probable causes before disassembling the pump.

WARNING

PRESSURIZED EQUIPMENT HAZARD

To reduce the risk of a serious injury whenever you are instructed to relieve pressure, follow the Pres- sure Relief Procedure on page 10.

 

SYMPTOM

 

PROBABLE CAUSE

TEST PROCEDURE

 

REMEDY

 

 

 

 

 

1.

Pump will not

Air is getting into the intake

 

 

 

prime

housing:

 

 

 

 

 

a. Defective o-ring (19) on in-

a.

Replace o-ring.

 

 

 

take manifold or accumu-

 

See page 15.

 

 

 

lator

 

 

 

 

 

b.

Suction hose/tube

not

b.

Tighten, or add

 

 

 

sealed

 

 

sealant to threads

 

 

 

 

 

 

 

2.

Pump will not

a.

Air supply turned off

 

a.

Turn air supply on

 

run

b.

Fluid valve turned off

 

b.

Turn fluid supply

 

 

 

 

 

 

 

 

 

valve on

 

 

c.

Air pressure regulator

c. Minimum air pressure

c.

Increase air pressure

 

 

 

set too low

on regulator 25 psi (175

 

regulator adjustment

 

 

 

 

kPa, 1.95 bar), depend-

 

 

 

 

 

 

ing on fluid being

 

 

 

 

 

 

pumped

 

 

 

 

d

Pilot valve assemblies

d. Remove tube ends from

d.

Repair or replace pilot

 

 

 

worn

hose studs. With air

 

valve assembly. See

 

 

 

 

supply on, alternately

 

page 22.

 

 

 

 

plug tube ends. If pump

 

 

 

 

 

 

runs, remove pilot

 

 

 

 

 

 

valves, inspect

 

 

 

 

e.

Air control valve

e. Check for air coming

e.

Repair or replace air

 

 

 

defective

from exhaust when

 

control valve. See page

 

 

 

 

pump is not running

 

20.

 

 

f.

Air piston quad ring (28)

f.

Replace quad ring. See

 

 

 

worn

 

 

page 18.

 

 

 

 

 

 

 

12 307843

Image 12
Contents Instructions-Parts List Series PumpsElectro-polished for use with waterborne coatings Table of Contents Skin Injection Hazard Equipment Misuse Hazard Fire and Explosion Hazard Installation Mounting the PumpGeneral Information Grounding Connect the Fluid Lines Connect the Fluid Suction LineConnect the Air Lines Ventilate the Air ExhaustPressure Relief Procedure Start and Adjust the PumpApplies only when using a spray gun or dispensing valve OperationPressurized Equipment Hazard Troubleshooting Symptom Probable Cause Test Procedure RemedyTroubleshooting Maintenance Check and Service the Lubricator, Regula- tor, and FilterFlush the Pump With Compatible Solvent Tighten Threaded ConnectionsService Repairing the Ball Check ValvesRepairing the Fluid Piston and Seal Service 46 or Repairing the Air Motor and Piston 02327 Repairing the Air Control Valve 40c 40h 40f 40g 40b 40n Repairing the Pilot Valve 72 5h Parts For pump Model 220663 only For pump Model 237008 only52*51 7326 For pump Model 220666 only For pump Model 237011 onlyParts For pump Model 220664 only For pump Model 237009 only5026 For pump Model 220667 only For pump Model 237012 only02334 For pump Model 220665 only For pump Model 237010 only02335 For pump Model 220668 only For pump Model 237013 onlyRef No Air Control Valve Ref No Pilot Valve Repair and Conversion Kits 220948 SEAT, carbide 108822 Repair and Conversion Kits Filter, Regulator, Lubricator Kit Filter, Regulator, Lubricator FRL KitDrum Cover Kit and Return Tube Kit Drum Cover KitReturn Tube Kit Return TubeSuction Kit Suction KitTechnical Data, 400 Series Pumps Performance Chart, 400 Series PumpsModel 220663 Model 220666Technical Data, 1200 Series Pumps Performance Chart, 1200 Series PumpsModel 220664 Model 220667Technical Data, 2500 Series Pumps Performance Chart, 2500 Series PumpsModel 220665 Model 220668Dimensional Drawing Mounting Hole LayoutGraco Standard Warranty Graco Information