Graco 220665, 220667, 220666, 237012, 220663, 237008 Connect the Air Lines, Ventilate the Air Exhaust

Page 9

Installation

Connect the Air Lines

1.Install the air line accessories to the left of the pump as shown in Fig. 4. Mount these accessories on the wall or on a bracket. Be sure the air line supplying the accessories is grounded.

2.Install a flexible air hose between the accessories and the 1/2 in. npt(f) air inlet (G). Use a minimum 1/2 in. ID air hose.

3.Install an air line lubricator (B) upstream from the pump air inlet for automatic pump lubrication.

4.Install a pump runaway valve (T) to sense when the pump is running too fast and shut off the air supply to the motor. To order a pump runaway valve, order Part No. 224040.

5.Install an air regulator (D) to control air inlet pres- sure.

WARNING

A bleed-type master air valve (C) is required in your system to relieve air trapped between this valve and the pump after the air regulator is closed. Trapped air can cause the pump to cycle unexpect- edly, which could result in serious bodily injury, including splashing in the eyes, injury from moving parts, or contamination from hazardous fluids.

6.Install one bleed-type master air valve (C) down- stream from the air regulator and use it to relieve trapped air. Locate the other master air valve up- stream from all air line accessories and use it to isolate the accessories during cleaning and repair.

7.Install an air line filter (A) to remove harmful dirt and moisture from your compressed air supply.

8.Install a grounded air supply line (P) with a mini- mum 1/2 in. ID. See Fig. 4.

Ventilate the Air Exhaust

WARNING

Improper handling of hazardous fluids or inhaling their vapors can cause serious bodily injury, even death. For your safety, it is imperative that you read all product warning labels and Material Safety Data Sheets (MSDS) for the fluids you are using. An MSDS can be obtained from your fluid suppliers. It is also important that you read and understand the warnings and precautions regarding HAZARDOUS FLUID HAZARD on page 5 before you operate.

All systems using hazardous fluid in enclosed areas or within buildings should have a properly designed and installed ventilation system. Consult your local building code and other industrial and governmental standards for proper design criteria.

N

T

 

 

 

L

 

 

D C

G

 

 

P

 

 

 

 

K

 

 

 

C

 

 

 

A

B

 

KEY

K

 

A

Air line filter

Main air line

B

Air line lubricator

L

Ground wire

C

Bleed-type master air valve

M

Intake manifold

D

Air regulator

N

Glutton pump

E

Fluid drain valve

P

Grounded air line

F

Fluid filter

R

Fluid supply

G

Pump air inlet

S

Fluid suction hose

H

Grounded fluid line

T

Runaway valve

JOutlet manifold

J F H

M

E

S

R

Fig. 4

02323

 

307843 9

Image 9
Contents Instructions-Parts List Series PumpsElectro-polished for use with waterborne coatings Table of Contents Skin Injection Hazard Equipment Misuse Hazard Fire and Explosion Hazard Installation Mounting the PumpGeneral Information Grounding Connect the Fluid Suction Line Connect the Fluid LinesVentilate the Air Exhaust Connect the Air LinesStart and Adjust the Pump Pressure Relief ProcedureApplies only when using a spray gun or dispensing valve OperationPressurized Equipment Hazard Symptom Probable Cause Test Procedure Remedy TroubleshootingTroubleshooting Check and Service the Lubricator, Regula- tor, and Filter MaintenanceFlush the Pump With Compatible Solvent Tighten Threaded ConnectionsService Repairing the Ball Check ValvesRepairing the Fluid Piston and Seal Service 46 or Repairing the Air Motor and Piston 02327 Repairing the Air Control Valve 40c 40h 40f 40g 40b 40n Repairing the Pilot Valve 72 5h Parts For pump Model 237008 only For pump Model 220663 only52*51 7326 For pump Model 237011 only For pump Model 220666 onlyParts For pump Model 237009 only For pump Model 220664 only5026 For pump Model 237012 only For pump Model 220667 only02334 For pump Model 237010 only For pump Model 220665 only02335 For pump Model 237013 only For pump Model 220668 onlyRef No Air Control Valve Ref No Pilot Valve Repair and Conversion Kits 220948 SEAT, carbide 108822 Repair and Conversion Kits Filter, Regulator, Lubricator FRL Kit Filter, Regulator, Lubricator KitDrum Cover Kit Drum Cover Kit and Return Tube KitReturn Tube Kit Return TubeSuction Kit Suction KitPerformance Chart, 400 Series Pumps Technical Data, 400 Series PumpsModel 220663 Model 220666Performance Chart, 1200 Series Pumps Technical Data, 1200 Series PumpsModel 220664 Model 220667Performance Chart, 2500 Series Pumps Technical Data, 2500 Series PumpsModel 220665 Model 220668Mounting Hole Layout Dimensional DrawingGraco Information Graco Standard Warranty