Graco 237010, 220667, 220666 Operation, Pressure Relief Procedure, Flush the Pump Before First Use

Page 10

Operation

Pressure Relief Procedure

WARNING

The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally. To reduce the risk of an injury from acci- dental spray from the gun, splashing fluid, or moving parts, always follow the Pressure Relief Procedure whenever you

Dare instructed to relieve the pressure

DStop spraying

DCheck or service any of the system equipment

Dinstall or clean the spray nozzle.

1.* Engage the spray gun or dispensing valve safety latch.

2.Shut off the air supply.

3.* Disengage the gun or dispensing valve safety latch.

4.* Hold a metal part of the gun or valve firmly to a grounded metal waste container and trigger it to relieve the fluid pressure.

5.* Engage the safety latch again.

6.Open the pump drain valve (required in system), and have a container ready to catch the drainage.

7.Leave the drain valve open until you are ready to spray again.

*Applies only when using a spray gun or dispensing valve.

If you suspect that the spray tip, nozzle, or hose is clogged or that pressure has not been fully relieved after following the steps above, very slowly loosen the hose end coupling and relieve pressure gradually, then loosen completely, then clear the tip, nozzle, or hose obstruction.

Flush the Pump Before First Use

WARNING

To reduce the risk of fluid injection injury, static sparking and splashing, read and follow Flushing Safety under FIRE OR EXPLOSION HAZARD on page 5.

The pump was tested with lightweight oil, which is left in to protect the pump parts. If this solution could con- taminate the fluid you are pumping, flush it thoroughly with a compatible solvent. To start the pump, follow the procedure in Start and Adjust the Pump, below.

Start and Adjust the Pump

NOTE: Check all fittings to be sure they are tight. Be sure to use a thread sealant compatible with the fluid being pumped on all male pipe threads.

1.Place the suction hose (S) in the fluid to be pumped. See Fig. 5.

2.Close the fluid drain valve (E).

3.With the air regulator (D) closed, open both bleed- type master air valves (C).

4.Open the fluid control device while continuing with the following steps.

5.Slowly open the air regulator (D). Adjust it until the pump runs smoothly.

6.Allow the pump to cycle slowly until all air is pushed out of the lines (the fluid will be flowing in a steady stream from the fluid outlet) and the pump is primed.

WARNING

To reduce the risk of component rupture, which could cause serious bodily injury, never exceed 100 psi (0.7 MPa, 7 bar) air supply pressure to the pump. Read the warning section EQUIPMENT MISUSE HAZARD on page 4.

10 307843

Image 10
Contents Series Pumps Instructions-Parts ListElectro-polished for use with waterborne coatings Table of Contents Skin Injection Hazard Equipment Misuse Hazard Fire and Explosion Hazard Mounting the Pump InstallationGeneral Information Grounding Connect the Fluid Lines Connect the Fluid Suction LineConnect the Air Lines Ventilate the Air ExhaustApplies only when using a spray gun or dispensing valve Pressure Relief ProcedureStart and Adjust the Pump OperationPressurized Equipment Hazard Troubleshooting Symptom Probable Cause Test Procedure RemedyTroubleshooting Flush the Pump With Compatible Solvent MaintenanceCheck and Service the Lubricator, Regula- tor, and Filter Tighten Threaded ConnectionsRepairing the Ball Check Valves ServiceRepairing the Fluid Piston and Seal Service 46 or Repairing the Air Motor and Piston 02327 Repairing the Air Control Valve 40c 40h 40f 40g 40b 40n Repairing the Pilot Valve 72 5h Parts For pump Model 220663 only For pump Model 237008 only52*51 7326 For pump Model 220666 only For pump Model 237011 onlyParts For pump Model 220664 only For pump Model 237009 only5026 For pump Model 220667 only For pump Model 237012 only02334 For pump Model 220665 only For pump Model 237010 only02335 For pump Model 220668 only For pump Model 237013 onlyRef No Air Control Valve Ref No Pilot Valve Repair and Conversion Kits 220948 SEAT, carbide 108822 Repair and Conversion Kits Filter, Regulator, Lubricator Kit Filter, Regulator, Lubricator FRL KitReturn Tube Kit Drum Cover Kit and Return Tube KitDrum Cover Kit Return TubeSuction Kit Suction KitModel 220663 Technical Data, 400 Series PumpsPerformance Chart, 400 Series Pumps Model 220666Model 220664 Technical Data, 1200 Series PumpsPerformance Chart, 1200 Series Pumps Model 220667Model 220665 Technical Data, 2500 Series PumpsPerformance Chart, 2500 Series Pumps Model 220668Dimensional Drawing Mounting Hole LayoutGraco Standard Warranty Graco Information