4.4.3.2 PF Loop Scale ASSY Affixing Procedure

When assembling the PF loop scale unit, the following exclusive tool should be used.

„ Exclusive tool No.#F731

: PF Loop Scale Affixing tool

 

(Code: 1051767)

The assembly procedure is given below.

1.Set the PF loop scale ASSY's double sided tape side on the grid roller side, align the internal diameter of the PF loop scale with the left end of the grid roller (PF roller) and set it lightly.

CAUTION At this point, the PF loop scale ASSY should not be fitted on the grid roller as far as it can go. If the PF loop scale ASSY is placed on

the grid roller by hand, it could damage the PF loop scale ASSY's internal diameter and the distance from the center of the grid roller

to the scale reading part would not be the same all around any more, resulting in a drop in the encoder sensor's reading accuracy.

2.Press the exclusive tool #F731 against the PF loop scale ASSY from the outside, then insert the grid roller in as far as the base plate carefully, and affix it.

Double sided tape

Protective backing

Figure 4-55. Affixing the Double Sided Tape to the PF Loop Scale

PF Loop Scale ASSY

Exclusive #F731 tool

 

Figure 4-56. Affixing the PF Loop Scale ASSY

Disassembly & Assembly

Disassembly and Assembly of Paper Feed Mechanism

188

Page 188
Image 188
Epson 9600, 7600 service manual PF Loop Scale Assy Affixing Procedure, Affixing the Double Sided Tape to the PF Loop Scale