EPSON Stylus Pro 7600/9600

Revision A

4.4.6 P_REAR Sensor ASSY

1.Remove the R Side Cover. (p.160)

2.Remove the L Side Cover. (p.163)

3.Remove the I/H Cover. (p.164)

4.Remove the H Top Cover. (p.165)

5.Remove the Rear Cover. (p.166)

6.Disconnect the connector (CN27: black 4-pin) of the P_REAR Sensor ASSY from the Main Board.

7.Push the Paper Hold Lever down to the front.

8.Remove the lower two screws (CBS: M4⋅6) securing the Paper Guide U.

(See Figure 4-60)

9.Remove the upper three screws (CBS: M4 ⋅ 6) (six screws for Stylus Pro 7600) securing the Paper Guide U and remove the Paper Guide U by pulling it up toward you slowly.

CAUTION When removing/installing the Paper Guide U, be careful not to mar the P_REAR Sensor ASSY with the edge of the sensor inspection

window.

10.Remove the two (CP(W): M2⋅8) screws securing the P_REAR Sensor ASSY and remove the P_REAR Sensor ASSY. (See Figure 4-61)

Screws (M46) 5

Paper Guide U

P_REAR Sensor ASSY peeping window

Figure 4-60. Removing the Paper Guide U

Screws (M28) 2

CHECK

POINT

ADJUSTMENT REQUIRED

The P_REAR Sensor ASSY position is adjusted at the factory before shipment. When the sensor bracket is to be removed on the service site, you are advised to mark the mounting position before removal for easy adjustment at reassembly.

If you replace the P_REAR Sensor ASSY, perform the necessary adjustment.

„Refer to “5.1.4.6 P_REAR Sensor ASSY Adjustment” (p.215)

P-REAR Sensor ASSY

Figure 4-61. Removing the P_REAR Sensor ASSY

Disassembly & Assembly

Disassembly and Assembly of Paper Feed Mechanism

191

Page 191
Image 191
Epson 7600, 9600 service manual Prear Sensor Assy, Window