EPSON Stylus Pro 7600/9600

Revision A

5.1.4.2 Main Board Adjustment

Described below are the adjustment items to be made once the MAIN Board (C472 MAIN) (p.207) has been replaced.

†Adjusting tools:

„ A3Tracing Paper #F751(Microtrace #300 LMB)

„A3 Copy Paper (PPC)

„Scale 1000mm #F713

„Scale Stopper #F714

†Work operations before adjustment:

„Parameter Backup (p.218)

„Firmware Reinstallation (p.219)

†Adjustment items (steps):

CHECK

When “Parameter Backup” has been executed, make the

POINT

adjustment by Procedure A in Table 5-4 below; there is no need of

 

following Procedure B.

 

 

Table 5-4. Required Adjustment Items (Main Circuit)

Procedure

Procedure

Adjustment Item

See

A*1

B*2

 

 

 

 

<Start the Self-diagnostic Function>

p.220

 

 

(Power OFF → [Paper Feed ]+[Paper Feed ]

 

 

 

+[Cut/Eject] → Power ON)

 

 

 

 

 

1

1

Rear Sensor AD Adjustment

p.231

2

2

Edge Sensor AD Adjustment

p.232

 

 

 

 

 

3

Initial Charge Flag Clear

p.257

 

4

Head Rank ID Checking

 

 

 

 

 

5

Head Rank Input

p.233

 

6

Head Nozzle Checking (Cleaning)

p.237

 

 

 

 

 

7

Head Slant Checking

p.246

 

8

Feed Correction + T&B Adjustment

p.239

 

 

 

 

 

9

Rear Sensor Position Adjustment

p.243

 

10

Platen Position Adjustment (Flash Point Adjustment)

p.244

 

 

 

 

Table 5-4. Required Adjustment Items (Main Circuit) (continued)

Procedure

Procedure

Adjustment Item

See

A*1

B*2

 

 

 

11

Round Trip Print Position Adjustment (Bi-D Adjustment)

p.248

 

12

Round Trip Print Position (Bi-D Adjustment) Checking

p.252

 

 

 

 

 

13

Head Gap Adjustment (Uni-D Adjustment)

p.253

 

14

USB ID Input

p.273

 

 

 

 

3

15

RTC writing initialization

p.71

 

16

Power Cleaning

p.259

 

 

 

 

 

17

Head Nozzle Checking (Cleaning)

p.237

 

18

Test Pattern Printing

p.255

 

 

 

 

Note "*1": Adjustment procedure when parameter backup has been executed "*2": Adjustment procedure when parameter backup can not be executed

†Work operations after adjustment:

„Replacing the maintenance tank and resetting the maintenance tank life counter

1.Replace the maintenance tank with a new one.

2.Start Maintenance Mode 2.

(Power OFF →[Paper Source]+[Eject]+[Paper Feed] → Power ON)

3.Clear the counter.

(“CLEAR COUNTERS”→“MAINTE. TANK”)

NOTE: For details, refer to 1.4.5 Maintenance Mode 2” (p.70).

Adjustment

Overview

213

Page 213
Image 213
Epson 7600, 9600 service manual Main Board Adjustment