5.3.5 Cover Sensor ASSY Mounting Position Adjustment

When removing/replacing the Cover Assembly or the Front Cover, verify the sensor operation using the Self-Diagnostic mode as described below.

NOTE: For disassembly and assembly procedure, refer to “Cover Sensor ASSY” (p.197).

1.Remove the Tube cover. See “Cover Sensor ASSY” (p.197).

2.Start the Self-diagnostic Function:

Power OFF → [Paper Feed ]+[Paper Feed ]+[Cut/Eject] → Power ON

3.Display “Test: Sensor”:

[SelecType >] [Paper Feed ] x2

4.Display “Sen: Cover”:

[SelecType >] [Paper Feed ] x1

5.Open and close the Front Cover, checking the LCD to make sure the message changes depending on the Front Cover position.

Table 5-31. Cover Sensor Assembly Check

Front Cover

 

LCD Message

Open

Sen: Cover

Open

 

 

 

Close

Sen: Cover

Close

 

 

 

Cover Sensor ASSY

6. If the correct message does not appear or any other message appears, verify the Cover

Figure 5-68. Adjusting the Cover Sensor ASSY Mounting Position

Sensor is installed correctly and check the operation again.

 

CHECK POINT

Acceptance Criterion:

The timing for cover opening is such that there is no gap between the front cover and the printer body which permits entrance of your finger.