5.1 Overview

This section describes the adjustment procedures necessary after replacing certain parts and explains how to perform those adjustment procedures.

5.1.1 Cautions

Before beginning the adjustment operation, be sure to confirm the following caution items.

CAUTION „ If you are carrying out adjustments, see 5.1.4 Adjustment

Items” (p.212) and then confirm the relevant adjustment items and adjustment procedures.

„ When carrying out adjustments, check the cautions displayed in the explanation for each adjustment item thoroughly. If the operation is performed wrong, it could hinder the product's operation or functions.

5.1.2 Adjustment Tools

CHECK

In adjustments and test printing, use Doubleweight Matte Paper

POINT

roll, unless otherwise specified.

 

 

Table below lists the tools necessary for adjustments of Stylus Pro 7600/9600.

Table 5-1. Adjustment Tools

Name

Part Code

Notes

Tension Gauge

1060744 / standard tool

2.2kgf ± 220g

#F770

acceptable

(PF Belt tension)

 

 

 

Thickness gauge

Commercially available

Thickness:

 

 

0.3 / 0.4 / 0.8 / 0.9 mm

Coupling tightening jig

 

Tightening force: 3kgf + 500g

 

 

 

Table 5-1. Adjustment Tools (continued)

Name

 

Part Code

Notes

24/44-inch Width Roll Paper

Epson or commercially

For printer mechanism

 

available paper

adjustments and test printing.

 

(Doubleweight Matte

 

 

Paper roll)

 

 

MCSP24R4

 

 

 

(24-inch width)

 

 

MCSP44R4

 

 

 

(44-inch width)

 

A3Tracing Paper

1057723

Used for adjustment of the

#F751

 

 

paper status detection sensor

 

 

 

(P_REAR) level adjustment.

 

 

 

Microtrace #300 LMB, made

 

 

 

by Kimoto

 

 

 

A3 Copy Paper (PPC)

Commercially available

Used for adjustment of the

 

product

paper status detection sensor

 

(Example: Fuji Xerox

(P_EDGE) level adjustment.

 

Bright Recycled)

 

Scale 1000mm

1047746 / A

Length:1000mm

#F713

commercially available

 

 

scale can be purchased.

 

Scale Stopper

1047745 / A

Used in combination with the

#F714

commercially available

#F713 (measurements in 0.1

 

scale can be purchased.

mm units)

CR ENC sensor positioning jig

1212926

 

#F799

 

 

 

 

 

 

Cutter Positioning Jig

1212928

 

#F800

 

 

 

PF ENC sensor positioning tool

1212925

 

#F798

 

 

 

 

 

 

 

Ink Cartridge (x7)*

 

 

Spare

Draining cartridge*

 

 

Use at black ink type change

 

 

 

 

Maintenance Tank*

 

 

Spare

 

 

 

 

Note "*": Use at adjustments which require test printing.