EPSON Stylus Pro 7600/9600 Revision A
Adjustment Self-diagnostic Function 251
5.2.3.14 Parameter Copying
In actual processing, at each point when the adjusted value is determined in
“5.2.3.13 Roun d Trip Print Position Adjustment (Bi-D Adjustment)” (p.248), the
compensation value obtained by computation is copied into each area. Actually,
therefore, copy processing by this function is not required. (See Figure 5-51)
5.2.3.15 Bi-D2 Adjustment (PG=0.7mm)
Make this adjustment, as required, after executing “5.2.3.13 Round Trip Print Position
Adjustment (Bi-D Adjustment)” (p.248).
The adjustment procedure is the same as that for “5.2.3.13 Round Trip Print Position
Adjustment (Bi-D Adjustment)” (p.248).
5.2.3.16 Bi-D3 Adjustment (PG=2.1mm)
Make this adjustment, as required, after executing “5.2.3.13 Round Trip Print Position
Adjustment (Bi-D Adjustment)” (p.248).
The adjustment procedure is the same as that for “5.2.3.13 Round Trip Print Position
Adjustment (Bi-D Adjustment)” (p.248).
Figure 5-51. Menu Transition for Parameter Copying
CHECK
P O I N T
When this adjustment is to be performed, use the following paper
since setting must be made for PG=0.7mm.
Paper to be used: Authentic glossy paper
(Example: Photo Glossy Paper #MCSRxxR2)
CHECK
P O I N T
When this adjustment is to be performed, use the following paper
since setting must be made for PG=2.1mm.
Paper to be used: Authentic plain paper roll (PMSPxxR6)
WAIT
Copy Param. ?
[Enter]