5.2.3.14 Parameter Copying

In actual processing, at each point when the adjusted value is determined in “5.2.3.13 Round Trip Print Position Adjustment (Bi-D Adjustment)” (p.248), the compensation value obtained by computation is copied into each area. Actually, therefore, copy processing by this function is not required. (See Figure 5-51)

5.2.3.15 Bi-D2 Adjustment (PG=0.7mm)

CHECK

When this adjustment is to be performed, use the following paper

POINT

since setting must be made for PG=0.7mm.

 

Paper to be used: Authentic glossy paper

 

(Example: Photo Glossy Paper #MCSRxxR2)

 

 

Make this adjustment, as required, after executing “5.2.3.13 Round Trip Print Position Adjustment (Bi-D Adjustment)” (p.248).

The adjustment procedure is the same as that for “5.2.3.13 Round Trip Print Position Adjustment (Bi-D Adjustment)” (p.248).

5.2.3.16 Bi-D3 Adjustment (PG=2.1mm)

CHECK

When this adjustment is to be performed, use the following paper

POINT

since setting must be made for PG=2.1mm.

 

Paper to be used: Authentic plain paper roll (PMSPxxR6)

 

 

Make this adjustment, as required, after executing “5.2.3.13 Round Trip Print Position Adjustment (Bi-D Adjustment)” (p.248).

The adjustment procedure is the same as that for “5.2.3.13 Round Trip Print Position Adjustment (Bi-D Adjustment)” (p.248).

Copy Param. ?

[Enter]

WAIT

Figure 5-51. Menu Transition for Parameter Copying