EPSON Stylus Pro 7600/9600

Revision A

8.Set the 0.9-mm thickness gauge between the PF Grid Roller and the Driven Roller near the detection arm on the paper transport path, and bring down the Paper Set Lever toward you (to the “paper holding” position).

At this point, if the value on the LCD is not “11”, loosen the screw securing the mounting plate for the P_THICK Sensor (right). Then slide the mounting plate to a position where the LCD shows “11”, tighten the screw and remove the 0.9-mm thickness gauge.

9.Set the 0.8-mm thickness gauge the same way as above and make certain that the value on the LCD is “01”.

At this point, if the value on the LCD is not “01”, loosen the screw securing the mounting plate for the P_THICK Sensor (right). Then slide the mounting plate to a position where the LCD shows “01”, tighten the screw and check the previous step again.

10.Turn the power switch Off, then after disconnecting the power cable, install the H Top Cover.

Table 5-30.

Mounting Plate

Gauge

Condition

LCD

Indication

 

 

 

 

 

 

 

P_THICK_0.3 Sensor Mounting

0.3 mm

Paper thickness

00

Plate (left)

0.3 mm or below

 

 

 

 

 

 

 

0.4 mm

Paper thickness

01

P_THICK Sensor Mounting Plate

0.8 mm

0.4 0.6 mm

 

(right)

0.9 mm

Paper thickness

11

 

 

0.7mm or above

 

 

 

 

 

Lever in “Up” position

10

 

 

(Paper released)

 

 

 

 

 

 

Lever in "Down" position

00

 

 

 

 

(Paper held)

 

 

 

 

 

 

 

CAUTION

Take care not to bend thickness gauges by, say, dropping. This adjustment requires an accuracy to units of 0.1 mm.

Adjustment

Mechanism Adjustment

266

Page 266
Image 266
Epson 9600, 7600 service manual Mounting Plate Gauge Condition, Lcd