EPSON Stylus Pro 7600/9600

Revision A

1.2.9 Ambient Conditions

1.2.9.1 Temperature/Humidity

Table 1-19. Temperature/Humidity

Condition

Temperature*1

Humidity*2

During operation

10 ~ 35°C

20 ~ 80%

 

 

 

During storage

-20 ~ 40°C

20 ~ 85%

During transport

-20 ~ 60°C

5 ~ 85%

 

 

 

Note *1: 120 hours max. at 60°C, one month max. at 40°C

*2: No condensation. These values are applicable only within the range as shown below.

Humidity (%)

Temperature (°C)

Figure 1-2. Environmental Conditions: Temperature/Humidity

1.2.9.2 Vibration

†

During operation:

0.15G, 10 ~ 55Hz X,Y and Z directions

†

During storage:

0.50G, 10 ~ 55Hz X,Y and Z directions

1.2.9.3

Shock

 

† During operation:

1G, 1ms max. X,Y and Z directions

† During storage:

2G, 2ms max. X,Y and Z directions

NOTE

1:

For storage, check that the print head is capped.

 

2:

Before transportation, check that the print head is capped, remove the ink

cartridges, and close the ink cartridge cover .

3: If the power to the printer is OFF with the printer head uncapped, turn the

power ON with the ink cartridges installed. Then wait until capping is completed, and turn the power OFF.

4: If the printer is left standing at temperature of -15°C or below, the ink in the print head and ink cartridges will freeze. If the ink is frozen, leave the printer standing at temperature of 25°C for more than three hours before its use.