4.6.2 Pump Motor ASSY

1.Remove the Maintenance ASSY. (See p.199)

2.Remove the two (M3⋅8) screws securing the Pump Motor ASSY to the Maintenance ASSY and remove the Pump Motor ASSY.

4.6.3 Cap ASSY

1.Remove the Maintenance ASSY. (See p.199)

2.Disconnect the tube which connect the Valve ASSY to the Cap ASSY.

3.Remove the two screws securing the Cap ASSY and remove the Cap ASSY from the Maintenance ASSY.

CAUTION Check for the points below when removing/mounting the Cap ASSY.

„Push the cap part down to the valve part and check that the cap

part rebounds with spring force.

„Check that the valve part is not dislocated.

Maintenance ASSY

Screws (M38) 2

Pump Motor ASSY

Figure 4-74. Removing the Pump Motor ASSY

Valve ASSY

Cap ASSY

Figure 4-75. Removing the Cap ASSY

Disassembly & Assembly

Disassembly and Assembly of Cleaning Mechanism