2.2.5 Others

COVER SENSOR

In order to detect whether the front cover on the lower front of this printer is open or closed, a cover sensor is mounted on the printer on the left side where the front cover opens and closes.

This sensor carries out control of operating and stopping of the CR motor and PF motor drive circuits via the MAIN board's logic circuit after detecting the cover's status. This control is the same when the paper support level is in the release state.

CIRCUIT BOARD PLACEMENT

The panel unit is located i the right front of the printer and the AC inlet, power supply circuit board and the MAIN circuit board are mounted in the compartment on the printer's rear side.

Panel Unit

Cover Sensor

Front Cover Flag

Front Cover

Figure 2-18. Cover Sensor Panel Unit

AC Inlet

Power Supply Circuit Board

MAIN Circuit Board

Figure 2-19. Circuit Board Layout

Operating Principles

Print Mechanism Components