4.6.4 Pump ASSY

1.Remove the Maintenance ASSY. (See p.199)

2.Remove the one central screw (M3⋅4) of the Pump ASSY and remove the three parts including the gear. (See Figure 4-76)

3.Remove the two screws (M3⋅6) on the gear side.

4.Disconnect the tube from the Cap ASSY, remove the one screw (M 3⋅6) and remove the Pump ASSY.(See Figure 4-77)

ADJUSTMENT

Once you have replaced the Pump ASSY, execute “CLEAR

REQUIRED

COUNTERS” (See p.71).

 

 

Gear (3 parts)

Screw (M34)

Screws (M36) 2

Figure 4-76. Removing the Pump ASSY 1/2

Pump ASSY

Screw (M36)

Ink tube

Figure 4-77. Removing the Pump ASSY 2/2

Disassembly & Assembly

Disassembly and Assembly of Cleaning Mechanism

201

Page 201
Image 201
Epson 7600, 9600 service manual Pump Assy, Once you have replaced the Pump ASSY, execute Clear, Counters See p.71