EPSON Stylus Pro 7600/9600

Revision A

4.4.5 P_THICK Sensor/P_THICK Sensor_0.3 ASSY

†P_THICK Sensor ASSY

†P_THICK_0.3 Sensor ASSY

1.Remove the R Side Cover. (p.160)

2.Remove the L Side Cover. (p.163)

3.Remove the I/H Cover. (p.164)

4.Remove the H Top Cover. (p.165)

5.Push the paper hold lever down to the rear.

6.Remove the harness from the connector of the P_THICK Sensor/P_THICK_0.3 Sensor.

7.Remove the one (CUPS: M3⋅6) screw securing the sensor bracket and remove the bracket along with the both sensors.

P_THICK_0.3 Sensor ASSY

Bring the Paper Set Lever into the release position and bring down the Detection Arm rearward.

P_THICK Sensor ASSY

Screws (M48) 2

CHECK

Sensor bracket position is adjusted at the factory before shipment.

POINT

When the sensor bracket is to be removed on the service site, you

 

are advised to mark the mounting position before removal for easy

 

adjustment at reassembly.

 

 

8.Unhook the sensor from the sensor bracket and remove the sensor.

ADJUSTMENT

If you move the sensor bracket position, perform the necessary

REQUIRED

adjustment.

 

„ Refer to “5.1.4.7 P_THICK/P_THICK_0.3 Sensor ASSY

 

Adjustment” (p.215)

 

 

Figure 4-59. P_THICK and P_THICK_0.3 Sensors Removal

Disassembly & Assembly

Disassembly and Assembly of Paper Feed Mechanism

190

Page 190
Image 190
Epson 9600 Pthick Sensor/PTHICK Sensor0.3 Assy, † Pthick Sensor Assy † PTHICK0.3 Sensor Assy, Adjustment at reassembly