ST-3050D SUBMERSIBLE PUMP/CTRL. BOX — PRE SETUP (CB200)

ELECTRONIC OVERLOAD UNIT SETTINGS

ElectronicOverloadUnit:Alwaysmakesurethat theelectronicunitsuppliedwiththecontrolboxisset to the correct amperage.This overload unit must MATCH the amperage requirements of the pump motor.

Using an electronic overload unit with incorrect settings may result in serious damage to the pump. Refer to the Pump Amperage Requirements Table (Table 7), for the correct overload amperage settings.

There are two dials on the Electronic Overload Unit (Figure 9) that require adjustment to meet the amperage requirement of the pump motor in use.

These dials are located on top of the overload unit and are labeled CLASS and FLC (A).

Use a phillips-head screw driver to adjust the dials to the correct settings.

FLC (A) Dial Setting

1.Set the FLC (A) dial pointer (Figure 9) to the correct amperage for the pump motor in use. Use Table 7, to determine the correct amperage setting.

ClassDialSetting

1.Set the CLASS dial pointer (Figure 9) to the HAND position 10. This controls the reset function only. It does not affect the ability of the pump to run with or without float switches.

RESETOperation

This electronic control unit has two modes of reset.The modes are defined as follows:

MODE 1

WhentheCLASSdialontheelectronicoverloadmodule isintheHAND position(manual)theresetbutton(Figure10)onthefrontofthecontrol box must be pushed to reset the unit (restore power) in the event of anoverload.

Figure 10. Control Box Reset Button

MODE 1

WhentheCLASSdialontheelectronicoverloadmoduleisintheAUTO position (automatic mode) the unit will automatically be reset in the event of an overload

NOTE

All Multiquip control boxes should have the CLASS dial set to the HAND position 10.

Figure 9. Electronic Overload Module

TABLE 7. PUMP MOTOR AMPERAGE REQUIREMENTSS

Pump Model

Control

Volts

Amps

Overload Unit

Box

(VAC)

 

 

 

 

 

 

 

 

ST3050D

CB200

230

14.2

AXE016-6.40-16A

Three-Phase

 

 

 

 

 

 

 

 

 

ST3050D

CB200

460

7.1

AXE016-6.40-16A

Three-Phase

 

 

 

 

 

 

 

 

 

Operation

1.From the voltage source set the circuit breaker or quick disconnect switch to the ON position.

2.For manual operation of the pump, place the 3-position operation switch (Figure 11) on the control box in the MANUAL position.

Figure 11. Manual-Off-On SW. (Man Position)

PAGE 20 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)

Image 20
Contents Multiquip Submersible Pump Model ST-3050D Heres HOW to GET Help ST-3050D Submersible Pump -TABLE of Contents ST-3050D Submersible PumpParts Ordering Procedures UPS Ground Service at no charge for freightST-3050D Submersible PUMP- Safety Message Alert Symbols Foryour Safety and the Safety of OthersGeneral Safety ST-3050D Submersible PumpEmergencies Maintenance SafetyST-3050D Submersible Pump Rules for Safe Operation ST-3050D Submersible Pump Specifications ST-3050D Submersible Pump General Information IntroductionST-3050D Submersible Pump Components Float Switch Dual ST-3050D Submersible Pump Application Float SwitchesFloat Switch Theory Overload Switch Listed Protection Capability Control BoxesST-3050D Submersible PUMP/CTRL. BOX Installation CB200 Phase Power Installation InputPower Cord Requirements Float Switch Installation CB200ST-3050D Submersible Pump 230/460VACVOLTAGE Selection 230/460VACVoltage SelectionST-3050D Submersible Pump Pumpwiring Diagram Pump Wiring DiagramST-3050D SUB. PUMP/CTRL. BOX Transformer Wiring CB200 Transformer 230/460VOLTAGE SettingsST-3050D SUB. PUMP/CONTRL. BOX Wiring Diagram CB200 Control Box Wiring DiagramPersonnel ST-3050D SUB. PUMP/CTRL. BOX 3Ø PWR. Installation CB200Phase Power Installation Outputto Pump ST-3050D SUB. PUMP/CTRL BOX 3Ø PWR. Installation CB200 ST-3050D Submersible PUMP/CTRL. BOX PRE Setup CB200 Electronic Overload Unit SettingsST-3050D Submersible PUMP/CTRL. BOX PRE Setup CB-200 Shut-DownElectronic Overload Setting 460 VAC, 3Ø ST-3050D SUB. PUMP/CTRL. BOX Installation MCP102/104Electronic Overload Setting 230 VAC, 3Ø ST-3050D SUB. PUMP/CTRL. BOX -WIRING Diagram MCP102/104 MCP102/104 Control Box ConfigurationsOperation Submersible Pump Upright Position IncorrectPump Shut-Down/Clean-up ST-3050D Submersible Pump OperationLubrication ImpellerST-3050D Submersible Pump -TROUBLESHOOTING Table X. Pump TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnST-3050D Suggested Spare Parts ST-3050D Electric Submersible Pump Assy Part Name QTY Remark ST-3050 D- Electric Submersible Pump Assy Part Name RemarkST-3050D Electric Motor Assy WASHER, Lock Effective October 1, 2002 Terms and Conditions of Sale Parts Page Heres HOW to GET Help