Multiquip manual ST-3050D Submersible Pump -TROUBLESHOOTING, Table X. Pump Troubleshooting

Page 27

ST-3050D SUBMERSIBLE PUMP TROUBLESHOOTING

TABLE X. PUMP TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

 

Check that proper voltage (230/460 3Ø) is being supplied to the

 

Incorrect voltage/amps?

pump. Also check that there is an adequate amount of current

 

 

(amps) to run the pump. Check power source circuit breaker.

 

 

 

 

Check electrical connections?

If using float switches check wiring, inspect power cord.

 

 

 

 

Blown power fuse?

Replace fuse, check cause of blown fuse.

Pump Fails To Start

 

 

Impeller locked?

Disconnect power cord and check for clogging and improper impeller

 

clearance. Unclog pump. Check overload protection device.

 

 

 

 

 

 

 

Use multimeter to check motor insulation. Insulation resistance must

 

Wet motor windings?

be approximately 15 megaohms. If resistance is low, disassemble

 

 

pump motor and bake windings to dry them.

 

 

 

 

Defective motor and pump

Check for excessive bearing wear, if worn replace bearings. Replace

 

bearings?

motor if defective.

 

 

 

 

Twisted or restricted discharge

Lay hose flat un-kinked. Remove clog from hose line.

 

hose?

 

 

 

 

 

Clogged pump strainer?

Clean strainer.

Pump Fails to Deliver Full

 

 

 

Use a voltmeter to check voltage while pump is energized. Voltage

Output

 

Low voltage?

must be within ±10%. Check power source (no load and load). If an

 

 

extension cord is used, make sure it has adequate current-carrying

 

 

 

 

capacity for the required length.

 

 

 

 

Impeller worn?

Replace impeller.

 

 

 

Water in Seal Oil

Defective water seal?

Replace water seal.

 

 

Loose Oil Fill Plug?

Tighten securely.

 

 

 

 

Performance Curve

 

(Feet)

90

 

 

 

 

 

Head

 

 

 

 

 

 

 

 

 

TOTAL HEAD

 

 

 

 

 

 

 

Total

 

 

 

 

Max 86 ft

 

 

 

 

 

CAPACITY

 

 

 

 

 

 

Figure 20.

 

60

 

 

 

Max 264 G.P.M

Performance Chart

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

0

100

200

300

Capacity(US.G.P.M)

 

 

 

 

ST-3050D — PARTS & OPERATION MANUAL — REV. 0 (11/18/02) — PAGE 27

Image 27
Contents Multiquip Submersible Pump Model ST-3050D Heres HOW to GET Help ST-3050D Submersible Pump ST-3050D Submersible Pump -TABLE of ContentsUPS Ground Service at no charge for freight Parts Ordering ProceduresForyour Safety and the Safety of Others ST-3050D Submersible PUMP- Safety Message Alert SymbolsST-3050D Submersible Pump General SafetyMaintenance Safety ST-3050D Submersible Pump Rules for Safe OperationEmergencies ST-3050D Submersible Pump Specifications Introduction ST-3050D Submersible Pump General InformationST-3050D Submersible Pump Components ST-3050D Submersible Pump Application Float Switches Float Switch TheoryFloat Switch Dual Control Boxes Overload Switch Listed Protection CapabilityFloat Switch Installation CB200 ST-3050D Submersible PUMP/CTRL. BOX Installation CB200Phase Power Installation Input Power Cord Requirements230/460VACVoltage Selection ST-3050D Submersible Pump 230/460VACVOLTAGE SelectionPump Wiring Diagram ST-3050D Submersible Pump Pumpwiring DiagramTransformer 230/460VOLTAGE Settings ST-3050D SUB. PUMP/CTRL. BOX Transformer Wiring CB200Control Box Wiring Diagram ST-3050D SUB. PUMP/CONTRL. BOX Wiring Diagram CB200ST-3050D SUB. PUMP/CTRL. BOX 3Ø PWR. Installation CB200 Phase Power Installation Outputto PumpPersonnel ST-3050D SUB. PUMP/CTRL BOX 3Ø PWR. Installation CB200 Electronic Overload Unit Settings ST-3050D Submersible PUMP/CTRL. BOX PRE Setup CB200Shut-Down ST-3050D Submersible PUMP/CTRL. BOX PRE Setup CB-200ST-3050D SUB. PUMP/CTRL. BOX Installation MCP102/104 Electronic Overload Setting 230 VAC, 3ØElectronic Overload Setting 460 VAC, 3Ø MCP102/104 Control Box Configurations ST-3050D SUB. PUMP/CTRL. BOX -WIRING Diagram MCP102/104Submersible Pump Upright Position Incorrect OperationST-3050D Submersible Pump Operation Pump Shut-Down/Clean-upImpeller LubricationTable X. Pump Troubleshooting ST-3050D Submersible Pump -TROUBLESHOOTINGItems Found In the Items Number Column Explanation of Code in Remarks ColumnST-3050D Suggested Spare Parts ST-3050D Electric Submersible Pump Assy Part Name QTY Remark ST-3050 D- Electric Submersible Pump Assy Remark Part NameST-3050D Electric Motor Assy WASHER, Lock Effective October 1, 2002 Terms and Conditions of Sale Parts Page Heres HOW to GET Help