cb200 wiring diagram
EXTERNAL |
| SINGLE PHASE WIRING |
|
|
|
|
| |||||
(230 VOLT) |
|
|
|
|
|
|
|
|
|
|
|
|
POWER SOURCE |
|
| CONNECTIONS |
|
|
|
| ELECTRONIC | ||||
|
|
|
|
|
|
|
| OVERLOAD UNIT | ||||
CIRCUIT |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| TERMINALS | ||
BREAKER |
|
|
|
|
|
| M | O/L |
|
|
|
|
L1 | RED |
|
|
|
|
|
|
|
|
| ||
|
|
|
| 1 |
|
| 2 |
|
|
| ||
| BLK | L1 |
|
|
|
|
| T1 |
| |||
|
|
|
|
|
|
|
|
| ||||
L2 |
| L2 |
|
|
| 3 |
|
| 4 | T2 | PUMP |
|
| GREEN | L3 |
|
|
|
|
| 6 |
| MOTOR |
| |
|
|
|
|
|
|
| T3 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 5 |
|
|
|
|
|
|
|
|
| H1 | H3 | H2 | H4 |
|
|
|
|
|
|
|
|
|
|
|
| CONTROL |
|
|
|
|
| |
GROUND |
|
|
|
| TRANSFORMER | SEE DETAIL “A” FOR JUMPER SELECTION | ||||||
|
|
| F1 |
|
| 50VA CPT |
| 230 VAC SELECTION. | ||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
ADD SUPPLIED JUMPER |
|
|
|
|
| 6 |
|
|
|
|
|
|
WIRE AS SHOWN FOR |
| XF | FUSE | X1 |
| X2 |
|
|
|
|
|
|
SINGLE PHASE OPERATION. |
|
|
|
|
|
|
|
| ||||
|
| 1/2 AMP |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ON |
|
|
|
|
|
| OFF |
|
|
|
| INDICATOR |
|
|
| ||
|
|
|
|
|
| LAMP |
|
|
| |||
| MANUAL | AUTO |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||||
| 5 |
|
| 1 |
|
| 1 | G | 7 |
|
|
|
|
| 11 |
|
|
|
|
|
|
|
|
| |
|
| 12 |
|
|
|
|
|
|
|
|
| |
|
|
|
| 4 |
|
|
| CONTACTOR |
|
|
| |
|
|
|
|
|
|
| 5 HP |
|
| O/L |
| |
|
| 23 | 24 |
|
|
|
|
|
|
| ||
|
|
| 3 | 1 | 1 | M | 7 |
|
| 6 | ||
|
|
|
|
|
|
|
|
|
|
|
| |
WARNING |
|
|
|
| 14 | 13 |
| A1 | A2 |
| 96 | 95 |
|
|
|
|
|
|
|
|
|
|
|
| |
CONTROL BOX INSTALLATION IS TO BE |
|
| 4 | 3 | 2 | 1 |
|
|
|
|
| |
PERFORMED BY A LICENSED ELECTRICIAN |
|
|
|
|
|
| TERMINAL |
|
|
|
| |
OR QUALIFIED PERSONNEL. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| BLOCK |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
THE POSSIBILITY OF ELECTRICAL SHOCK |
|
|
|
|
|
|
|
|
|
|
| |
OR ELECTROCUTION EXISTS, WHICH COULD |
|
|
|
|
|
|
|
|
|
|
| |
CAUSE SEVERE BODILY HARM EVEN DEATH!. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| STOP | START |
|
|
|
|
|
|
|
|
|
|
| FLOAT | FLOAT |
|
|
|
|
|
|
|
|
|
|
| SWITCH | SWITCH |
|
|
|
|
|
|
DETAIL “A”
L1 |
|
| L2 | L1 |
|
| L2 |
JUMPER | 230V INPUT |
|
| 460V INPUT |
| ||
|
|
|
|
|
|
| |
TAB |
|
|
|
|
|
|
|
H1 | H3 | H2 | H4 | H1 | H3 | H2 | H4 |
| SERIES |
|
| PARALLEL |
| ||
CONNECTION |
|
| CONNECTION |
NOTES
SINGLE PHASE INSTALLATION
The transformer connections must be set up for 230 volts. Reference detail “A”. Add the supplied jumper wire between terminal 4 of the electronic overload unit and L3 on the input terminal block.
ELECTRONIC OVERLOAD MODULE
This control box is equipped with an electronic overload unit. The FLC (A) dial on the overload module must be set in accordance with the require- ments of the pump.
Figure 26. CB200 Wiring Diagram
st3020b1/BCUL Sub. pump • operation and parts manual — rev. #2 (10/28/10) — page 29