Multiquip st3020b1, st3020bcul manual Maintenance, Impeller/Mechanical Seal Replacement

Page 25

maintenance

Inspecting Lubrication Oil (Mechanical Seal)

1.Block the oil fill opening with a finger and roll pump to one side to drain (Figure 22) oil into a small transparent container.

2.If oil is cloudy (milky) or has water in it, indicates that mechanical seal is defective or worn. Replace mechanical seal.

Figure 22. Lubrication Oil Inspection

Impeller/Mechanical Seal Replacement

Refer to the the following procedure and Figure 23 for the removal of the impeller and mechanical seal.

1.Remove the three strainer bolts (item 147) that secure, strainer to the suction cover (item 176). Remove strainer (item 146).

2.Remove the four suction cover bolts (item 177) that secure the suction cover (item 176) to the casing (item 1). Remove suction cover.

3.Remove suction cover packing (item 179) from suction cover and friction disc (items 176 and 2).

4. Remove impeller nut (item 4) and washer (item 53).

2

5. Remove impeller (item 3) and impeller key (item 6) from motor shaft. Remove mechanical seal (item 60).

6.Remove adjustment liner (item 47).

7.Reassemble in reverse order.

Figure 23. Impeller/Mechanical Seal Removal

st3020b1/BCUL Sub. pump • operation and parts manual — rev. #2 (10/28/10) — page 25

Image 25
Contents Model st3020b1/st3020bcul Submersible Pump Table of ContentsChoose from three easy options SaFetY messages Safety InformationGeneraL saFetY „ do not attempt to thaw out a frozen pump by using PUmp saFetYControl box safety Power Cord/Cable SafetyLiFting saFetY Grounding SafetyST3020B1/BCUL Pump Dimensions DimensionsST3020B1/BCUL SpecificationSUL/CSA Pump Performance Curve Performance curveGeneral information Shaft simplifies maintenance„„CORROSION-RESISTANT STAINLESS-STEEL Submersible Pump Components ComponentsDirect Power Operation Direct power operationMechanical Float Switch Float switchesDesign Features How It WorksMounting The Float Switches Float SwitchesControl Boxes CB6 and CB200 Float switches control boxSingle Power Input Cable to Control BOX For correct wiring to pump motor 1Ø, 230 VAC, addOperation Pump Power Connections No Control BoxHose Connections Attaching Lifting RopeSingle-Phase Power Installation Input Control Box InstallationPower Cord Requirements Control Box MountingConnecting AC Power to the Pump Motor Connecting Dual float Switch SW-1WOP To Control BoxReset Operation Electronic Overload Module SettingsModule CB200 Control Box New Style Electronic Overload ModuleAutomatic Operation Manual OperationCleanup Operation/maintenanceVerify that the control box power on light is OFF Shut-DownImpeller/Mechanical Seal Replacement MaintenanceRemove adjustment liner item Reassemble in reverse order Remove impeller nut item 4 and washer itemWhy perform electrical insulation testing? Electrical Insulation TestingSolution SymptomTB1 Cb6 wiring diagramConnections Cb200 wiring diagramExplanation of Code in Remarks Column To 3 Units Suggested Spare PartsPump assy Part Name QTY Remarks Motor assy Part Name FreigHt poLiCY Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

st3020bcul, st3020b1 specifications

The Multiquip ST3020B1 and ST3020BCUL are robust and efficient generators designed to meet the power needs of various applications. These models are particularly popular among contractors, events, and emergency services due to their reliability and high performance.

One of the main features of the ST3020B1 is its impressive power output. With a rated capacity of 30 kW, this generator is capable of powering a variety of tools and equipment simultaneously. The ST3020BCUL variant, while also maintaining similar power output, offers additional features that enhance usability and functionality. Both models are equipped with a durable frame and come with advanced noise-reduction technology, making them suitable for use in noise-sensitive environments.

The design of the ST3020B1 and ST3020BCUL emphasizes portability. Both models are fitted with heavy-duty wheels and ergonomic handles, allowing for easy maneuverability across job sites. Their compact design ensures that they occupy minimal space without compromising on performance.

In terms of technology, these generators are powered by a reliable engine that guarantees consistent performance. The advanced fuel consumption management system enhances efficiency, allowing longer operational periods before refueling. Additionally, the generators are designed with user-friendly control panels that provide clear indicators for oil levels, battery voltage, and running status, ensuring easy monitoring during operation.

Safety features are paramount in the design of the ST3020B1 and ST3020BCUL. Both models are equipped with Automatic Low Oil Shutdown systems, preventing engine damage and ensuring longevity. The overload protection mechanism safeguards against potential equipment damage by automatically shutting down the generator when necessary.

Moreover, the ST3020BCUL model goes a step further by integrating additional outputs, including multiple 120V and 240V outlets, catering to diverse power requirements. This versatility makes it ideal for both professional construction environments and recreational applications.

In summary, the Multiquip ST3020B1 and ST3020BCUL generators stand out for their powerful output, portability, user-friendly technology, and safety features. These characteristics make them an essential tool for anyone requiring reliable mobile energy solutions, contributing significantly to enhanced productivity and efficiency in various operational settings.