Multiquip st3020b1, st3020bcul manual Symptom, Solution

Page 27

TROUBLESHOOTING

Table 8. Pump Troubleshooting

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

 

Check that proper voltage (230 VAC, 60 Hz, single-

 

Incorrect voltage/amps?

phase) is being supplied to the pump. Also check that

 

there is an adequate amount of current (amps) to run

 

 

 

 

the pump. Check power source circuit breaker.

 

 

 

 

Check electrical connec-

If using float switches check wiring, inspect power

 

tions?

cord.

 

 

 

 

Blown power fuse or tripped

Replace fuse check circuit breaker, check cause of

Pump Fails To Start

circuit breaker?

blown fuse or tripped breaker.

 

 

Impeller locked?

Disconnect power cord and check for clogging. Un-

 

 

clog pump. Check overload protection device.

 

 

 

 

 

 

 

Use multimeter to check motor insulation. Insulation

 

Wet motor windings?

resistance must be approximately 15 megaohms. If

 

resistance is low, disassemble pump motor and bake

 

 

 

 

windings to dry them.

 

 

 

 

Defective motor and pump

Check for excessive bearing wear, if worn replace

 

bearings?

bearings. Replace motor if defective.

 

 

 

 

Twisted or restricted dis-

Lay hose flat un-kinked. Remove clog from hose line.

 

charge hose?

 

 

 

 

 

 

Clogged pump strainer?

Clean strainer.

 

 

 

Pump Fails to Deliver Full

 

Use a voltmeter to check voltage while pump is

Output

 

energized. Voltage must be within ±10%. Check

 

Low voltage?

power source (no load and load). If an extension cord

 

 

is used, make sure it has adequate current-carrying

 

 

capacity for the required length. See Table 4.

 

 

 

 

Impeller worn?

Replace impeller.

 

 

 

Water in Mechanical

Defective mechanical seal?

Replace mechanical seal.

 

 

Seal Oil

Loose Oil Fill Plug?

Tighten securely. Apply teflon tape.

 

 

 

 

st3020b1/BCUL Sub. pump • operation and parts manual — rev. #2 (10/28/10) — page 27

Image 27 Contents
Model st3020b1/st3020bcul Submersible Pump Table of ContentsChoose from three easy options SaFetY messages Safety InformationGeneraL saFetY „ do not attempt to thaw out a frozen pump by using PUmp saFetYGrounding Safety Power Cord/Cable SafetyControl box safety LiFting saFetYST3020B1/BCUL Pump Dimensions DimensionsSpecificationS ST3020B1/BCULUL/CSA Pump Performance Curve Performance curveShaft simplifies maintenance General information„„CORROSION-RESISTANT STAINLESS-STEEL Submersible Pump Components ComponentsDirect Power Operation Direct power operationHow It Works Float switchesMechanical Float Switch Design FeaturesMounting The Float Switches Float SwitchesControl Boxes CB6 and CB200 Float switches control boxSingle Power Input Cable to Control BOX For correct wiring to pump motor 1Ø, 230 VAC, addAttaching Lifting Rope Pump Power Connections No Control BoxOperation Hose ConnectionsControl Box Mounting Control Box InstallationSingle-Phase Power Installation Input Power Cord RequirementsConnecting AC Power to the Pump Motor Connecting Dual float Switch SW-1WOP To Control BoxCB200 Control Box New Style Electronic Overload Module Electronic Overload Module SettingsReset Operation Module Automatic Operation Manual OperationShut-Down Operation/maintenanceCleanup Verify that the control box power on light is OFFRemove impeller nut item 4 and washer item MaintenanceImpeller/Mechanical Seal Replacement Remove adjustment liner item Reassemble in reverse orderWhy perform electrical insulation testing? Electrical Insulation TestingSolution SymptomTB1 Cb6 wiring diagramConnections Cb200 wiring diagramExplanation of Code in Remarks Column To 3 Units Suggested Spare PartsPump assy Part Name QTY Remarks Motor assy Part Name FreigHt poLiCY Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help