Drolet 1400-I owner manual Installation Instructions

Page 10

2.4Installation Instructions

1.Inspect the fireplace according to the safety information and fireplace requirements and have it cleaned and/or upgraded as necessary.

2.If the installation of the unit renders the existing damper control inaccessible, it will be necessary to either secure the damper wide open or remove it entirely. An inaccessible damper, which may close, could cause smoke to enter the room. This creates a potential health hazard.

3.CONNECTOR INSTALLATION: A flue connector may provide acceptable performance, however, we recommend the use of a chimney liner to ensure satisfactory performance. Slip connectors for continuous liners should also be installed. Use Listed Chimney Liners – UL1777, CAN/ULC-S635. The connector must be secured with a minimum of three screws.

4.ATTENTION INSTALLER: When positioning the unit in a fireplace opening prior to the flue installation, install the insert into the opening until the top lip of air jacket is flush with fireplace facing.

Figure 2.2

Figure 2.3

4.If lag-bolts and anchors are to be used to secure the insert, the hole locations should be marked with the unit in place. Remove the insert and locate the anchors.

5.Remove the faceplate panels from their box and assemble according to the following instructions.

9

Image 10
Contents Escape 1400-I Insert Introduction Table of Contents Escape 1400-I Dimensions Pre-Installation Requirements Masonry & Zero Clearance RequirementsVenting Requirements Installation Clearances To Combustibles Measured From Insert BodySuitable Fireplace Dimensions Hearth RequirementsSafety Information Installation Instructions Air control plate, faceplate and fan Assembly Instructions OperationSafety Information Fuel Simple Wood Moisture Test Lighting a FireDraft Settings Maintaining The Fire Fan OperationGlass Cleaning and maintenance MaintenanceCare And Cleaning Ash RemovalChimney Cleaning Creosote Formation And Need For RemovalBaffle Installation for Escape Baffle installation & removal for EscapeSecondary Air Tube Replacement Important NotesSecondary Air Tube replacement Fan Maintenance & Care Removal instructionsSpecifications Escape 1400-I Insert ModelDrolet Limited Lifetime Warranty