Drolet 1400-I owner manual Installation, Clearances To Combustibles Measured From Insert Body

Page 7

Section 2.0 Installation

2.1 Clearances To Combustibles (Measured From Insert Body)

 

Escape 1400-I

Sidewall (A)

13” (330 mm)

Shelf (B)

22” (559 mm)

Side mantle (C)

10” (254 mm)

Top mantel (D)

29” (737 mm)

Table 2.1

CLEARANCES

Figure 2.1

Note: If side mantle protrudes more than 1.5” (38mm) in front of face of fireplace, then use sidewall clearance.

6

Image 7
Contents Escape 1400-I Insert Introduction Table of Contents Escape 1400-I Dimensions Masonry & Zero Clearance Requirements Pre-Installation RequirementsVenting Requirements Clearances To Combustibles Measured From Insert Body InstallationHearth Requirements Suitable Fireplace DimensionsSafety Information Installation Instructions Operation Air control plate, faceplate and fan Assembly InstructionsSafety Information Fuel Lighting a Fire Simple Wood Moisture TestDraft Settings Fan Operation Maintaining The FireAsh Removal MaintenanceCare And Cleaning Glass Cleaning and maintenanceCreosote Formation And Need For Removal Chimney CleaningBaffle installation & removal for Escape Baffle Installation for EscapeImportant Notes Secondary Air Tube ReplacementRemoval instructions Secondary Air Tube replacement Fan Maintenance & CareEscape 1400-I Insert Model SpecificationsDrolet Limited Lifetime Warranty