Drolet 1400-I owner manual Secondary Air Tube Replacement, Important Notes

Page 20

4.5 Secondary Air Tube Replacement

(see Figure 4.3)

1.Remove cotter pin at RH end of tube.

2.Slide tube to left and lower tube end below RH plenum.

3.Slide tube to right to remove.

4.Reassemble in reverse order using a new cotter pin. The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer.

5.Note that any tube can be replaced without disturbing the baffle.

Important Notes:

The air tubes are identified for placement as follows:

Front to back: Tube No. 1 41 Holes of .156” diameter

Tube No. 2 81 Holes of .109” diameter

Tube No. 3 81 Holes of .109” diameter

19

Image 20
Contents Escape 1400-I Insert Introduction Table of Contents Escape 1400-I Dimensions Pre-Installation Requirements Masonry & Zero Clearance RequirementsVenting Requirements Installation Clearances To Combustibles Measured From Insert BodySuitable Fireplace Dimensions Hearth RequirementsSafety Information Installation Instructions Air control plate, faceplate and fan Assembly Instructions OperationSafety Information Fuel Simple Wood Moisture Test Lighting a FireDraft Settings Maintaining The Fire Fan OperationMaintenance Care And CleaningGlass Cleaning and maintenance Ash RemovalChimney Cleaning Creosote Formation And Need For RemovalBaffle Installation for Escape Baffle installation & removal for EscapeSecondary Air Tube Replacement Important NotesSecondary Air Tube replacement Fan Maintenance & Care Removal instructionsSpecifications Escape 1400-I Insert ModelDrolet Limited Lifetime Warranty