Drolet ECO-35 owner manual Unit Controls, Opening Door, Convection Blowers Room AIR FAN

Page 12

UNIT CONTROLS

The blowers and automatic fuel supply are controlled from the panel on the ECO-35. The control panel functions are as follows:

Note:

1- To display the available functions, just touch the control board at any place 2- Select the desired function

*The display will turn itself off after 2 minutes.

MODE BUTTON

When the on-off button is pressed, the stove will automatically ignite. The heat level must be selected manually to adjust the stove’s heat output to the desired level. If the thermostat mode is selected, the stove will automatically modulate between the lowest heat level and the heat level selected to keep the room temperature at the thermostat’s setting. If the set room temperature is achieved while the stove has been running at the lowest heat level for more than 45 minutes, the unit will automatically shut off and will start another ignition cycle only when the thermostat calls for heat again(stove have to cool down completely prier to ignite). No fire starter is necessary to ignite the unit. The auger will feed fuel for 4 minutes and the electronic igniters will stay on for 10 minutes. If the unit doesn’t ignite within 15 minutes, the stove will wait for 5 minutes and will start a

second ignition cycle. If ignition fails a second time, a warning message will appear on control panel.

The Heat Level may be selected during the ignition cycle and can be modified in heating mode. However, the unit will only feed fuel at the desired heat level setting when the heat sensor located into the stove will receive a signal indicating that the unit has been fully ignited. This may take anywhere between 10 and 15 minutes.

FUEL FEED SWITCH

By activating this function, the stove start to feed for 1 minute and the display start to blink. You can stop the distribution by touching the sign a second time or by starting the stove.

CAUTION: THIS FUNCTION CAN ONLY BE OPERATED WHEN THE STOVE IS IN “OFF” POSITION. THE FUEL FEED SWITCH IS USED TO PRIME THE AUGER WHEN THE AUGER IS EMPTY.

NOISE REDUCER

The convection blowers speed varies directly with the fuel feed rate. A dimmed display indicates that the blowers are in low noise mode.

When the “NOISE REDUCER” button is pushed, the convection blowers will switch to their lowest speed. The convection blowers will remain at their lowest speed unless the stove reaches a certain temperature. If this occurs, the convection blowers will go back to their highest setting to cool down the stove. The low noise button will have to be pressed again for the convection blowers to go back to their lowest speed. Please note that the difference in noise level may not be noticeable on units manufactured after 2006. Those units already use two ultra-quiet tubeaxial convection blowers that produce a very low noise even at full speed.

HEAT LEVEL

By pressing the gradient, you can set the pellet feed rate and hence the heat output of your stove. The levels of heat output will change and each gradient will indicate the level from 1 to 6.

RESET

The reset button has to be used to clear any warning on the control and restart your stove. This button is only available when you get a warning code on the display.

OPENING DOOR

The door should be open only for maintenance purposes.

CONVECTION BLOWERS (ROOM AIR FAN)

Upon starting your stove, the convection blowers will not come on until the stove’s heat exchanger warms up. This usually takes about 10 to 15 minutes from start-up. Speed will vary with the selected feed rate, except if the noise reducer mode has been activated.

12

Image 12
Contents Model ECO-35 Freestanding 45266Register YOU Warranty Online IntroductionSafety Precautions Table of Contents Troubleshooting Stove Stops Feeding Pellets and Shows Warning Code dStove Installation Back wall installationCorner installation Floor protection Rear view Fresh air supplyVentilated crawl space Installation Configurations Venting through wallVenting trough wall Equivalent Vent Lenght EVLRefer to & 10 for basement installation Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Venting through masonry chimneyVenting through side Masonry chimney Vertically Into Existing Masonry FireplaceLighting Procedure OperationProper Fuel PRE-START-UP CheckUnit Controls Opening DoorConvection Blowers Room AIR FAN Shutdown Procedure Safety FeaturesIf the Stove Runs OUT of Pellets Damper ControlDamper operation Damper OperationOperating the Stove Using a Thermostat Thermostat InstallationThermostat terminal Thermostat locationOperating Safety Precautions Please Read thisMaintenance Baffle & exhaust access panelCleaning rod Ash drawer ASH RemovalCleaning Baffle removalVaccum USE Exhaust blower cleaning Blowers and Pressure Switch ProbeChimney Cleaning Recommended Maintenance ScheduleTroubleshooting Removal and Replacement of Broken Door GlassStove Shuts OFF and Shows Warning Code P Stove Shuts OFF and Displays Warning Code E Auger motor has failedStove Feeds PELLETS, but will not Ignite Shows Warning Code Stove Stops Feeding Pellets and ShowsSmoke Smell Coming Back Into the Home Auger Motor Stops Feeding Pellets and Comes Back onStove is Running but Displays Warning Code Smoke Smell or Soot BUILD-UP Message Corresponding WarningElectrical Diagram Electrical diagramComponents left side Components rear Components right sideReplacement Parts Horizontal and Vertical Vent Chart Appendix aIndicate Appliance Code Description of the Problem Appendix BDrolet Limited Lifetime Warranty Description