Drolet ECO-35 owner manual Stove is Running but Displays Warning Code

Page 24

THE STOVE IS RUNNING BUT DISPLAYS WARNING CODE

Possibles Causes:

Possibles Remedies:

 

 

Warning generated by a power failure while the stove was running.

The stove will restart on the initial setting once it cools off.

 

Note: For a short power failure (less than 5 seconds), the stove will continue to function at

 

the selected speed.

The control board does not display any information.

Possible Causes:

Possible Remedies :

 

 

1. A fuse on the control board has blown.

Remove the control board. Check if the F2 fuse on the back of it appears

 

to be bad. Replace it with a 7.5 Amp 250 Volt fuse. Plug the stove back in

 

and try to run the unit.

GLASS SOOTS UP VERY FAST

FLAME IS LAZY, DARK, AND HAS BLACK TIPS

AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS

Possible Causes:

Possible Remedies:

 

 

 

1.

Stove or vent pipe is clogged, which restricts airflow through the burn pot.

Follow all cleaning procedure in the maintenance section of the owner’s

 

 

manual.

 

 

 

2.

Vent pipe installed improperly.

Check to make sure the vent pipe has been installed according to the

 

 

instructions in the owner’s manual.

 

 

 

3.

The air damper is too far closed for a higher setting.

Slide the air supply to a higher setting and try to burn the unit again.

 

 

 

4.

Burn pot holes are blocked.

Remove the burn pot and clean it thoroughly.

 

 

 

5.

Blockage in air intake pipe.

Visually inspect the air intake pipe that leads into the burn pot for foreign

 

 

material.

 

 

 

6.

Combustion/exhaust blower is not spinning fast enough.

Test the RPM on the blower (separately – bypassing the control board) after the

 

 

blades have been cleaned. The RPM should be approximately 3000 RPM. You

 

 

will need a technician to perform this test.

 

 

 

7.

Bad pellets

The brand or the batch of pellets used may be of poor quality. If possible, try a

 

(Applies to “GLASS SOOTS UP AT A VERY FAST RATE” Only)

different brand of pellets. You might also want to try a brand that is made from

 

 

a different type of wood (softwood vs. hardwood). Different woods have

 

 

different characteristics that affect the combustion. Your pellets may also be too

 

 

humid. Make sure you store your fuel properly, in a dry ventilated area.

 

 

 

24

Image 24
Contents Model ECO-35 Freestanding 45266Register YOU Warranty Online IntroductionSafety Precautions Table of Contents Troubleshooting Stove Stops Feeding Pellets and Shows Warning Code dStove Installation Back wall installationCorner installation Floor protection Rear view Fresh air supplyVentilated crawl space Installation Configurations Venting through wallVenting trough wall Equivalent Vent Lenght EVLRefer to & 10 for basement installation Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Venting through masonry chimneyVenting through side Masonry chimney Vertically Into Existing Masonry FireplaceLighting Procedure OperationProper Fuel PRE-START-UP CheckUnit Controls Opening DoorConvection Blowers Room AIR FAN Shutdown Procedure Safety FeaturesIf the Stove Runs OUT of Pellets Damper ControlDamper operation Damper OperationOperating the Stove Using a Thermostat Thermostat InstallationThermostat terminal Thermostat locationOperating Safety Precautions Please Read thisMaintenance Baffle & exhaust access panelCleaning rod Ash drawer ASH RemovalCleaning Baffle removalVaccum USE Exhaust blower cleaning Blowers and Pressure Switch ProbeChimney Cleaning Recommended Maintenance ScheduleTroubleshooting Removal and Replacement of Broken Door GlassStove Shuts OFF and Shows Warning Code P Stove Shuts OFF and Displays Warning Code E Auger motor has failedStove Feeds PELLETS, but will not Ignite Shows Warning Code Stove Stops Feeding Pellets and ShowsSmoke Smell Coming Back Into the Home Auger Motor Stops Feeding Pellets and Comes Back onStove is Running but Displays Warning Code Smoke Smell or Soot BUILD-UP Message Corresponding WarningElectrical Diagram Electrical diagramComponents left side Components rear Components right sideReplacement Parts Horizontal and Vertical Vent Chart Appendix aIndicate Appliance Code Description of the Problem Appendix BDrolet Limited Lifetime Warranty Description