Drolet ECO-35 owner manual Stove Shuts OFF and Displays Warning Code E, Auger motor has failed

Page 21

STOVE SHUTS OFF AND DISPLAYS WARNING CODE “E”

Possible Causes:

Possible Remedies: (Unplug stove first when possible)

 

 

 

1.

The hopper is empty.

Refill the hopper.

 

 

 

2.

The burn pot holes are blocked.

Remove the burn pot and clean it thoroughly.

 

 

3. The air damper is open too much for the low feed setting.

If the stove is on the low setting, you may need to close the damper all the way.

 

 

Slide the air supply control toward the minimum setting.

 

 

 

4.

The air inlet, interior chambers, or exhaust system is partly blocked.

Follow all cleaning procedures in the maintenance section of the owner’s

 

 

manual.

 

 

 

5.

The auger motor has failed.

Remove the auger motor from the auger shaft and try to run the motor separately by

 

 

pressing the fuel feed button on the control board. If the motor turns, the shaft is

 

 

jammed on something. If the motor does not turn, the motor is defective or there is a

 

 

faulty connection with the control board. To remove the auger motor, take the rear

 

 

panel off the stove body. Loosen the two screws holding the motor to the auger

 

 

shaft.

 

 

 

6.

The auger shaft is jammed.

Remove the auger shaft from the auger housing. Start by emptying the hopper. Take

 

 

the rear panel off the stove body. Then take the auger motor off by removing the

 

 

screws that hold the motor to the auger shaft. Once the motor is out, remove the four

 

 

screws on the steel plate that holds the auger shaft to the auger housing. Then rotate

 

 

the bottom end of the auger shaft down towards you until you can pull the shaft

 

 

down out of the stove. After you have removed the shaft, inspect it for bent flights,

 

 

burrs, or broken welds. Remove any foreign material that may have caused the jam.

 

 

Also, check the auger housing for signs of damage such as burrs, rough spots, or

 

 

grooves cut into the metal that could have caused a jam. Clean the auger housing

 

 

thoroughly to remove all pellet dust.

 

 

 

7.

The thermistor heat sensor has malfunctioned.

The thermistor is a heat sensor located on the exhaust housing. Its function

 

 

is to tell the control board that the unit has ignited properly by measuring the

 

 

heat in the exhaust. The pellet stove will not start feeding pellets at the

 

 

desired heat setting until it has received a signal from the thermistor heat

 

 

sensor. If the thermistor heat sensor is bad, the unit will stop after the

 

 

ignition cycle. If this situation occurs, call your dealer or technician.

 

 

 

21

Image 21
Contents 45266 Model ECO-35 FreestandingIntroduction Register YOU Warranty OnlineSafety Precautions Table of Contents Stove Stops Feeding Pellets and Shows Warning Code d TroubleshootingStove Installation Back wall installationCorner installation Floor protection Rear view Fresh air supplyVentilated crawl space Venting through wall Installation ConfigurationsVenting trough wall Equivalent Vent Lenght EVLVertically Into Existing Chimney System Refer to & 10 for basement installationVenting through masonry chimney Installation Through Side of Masonry ChimneyVenting through side Masonry chimney Vertically Into Existing Masonry FireplaceOperation Lighting ProcedureProper Fuel PRE-START-UP CheckUnit Controls Opening DoorConvection Blowers Room AIR FAN Safety Features Shutdown ProcedureIf the Stove Runs OUT of Pellets Damper ControlDamper Operation Damper operationThermostat Installation Operating the Stove Using a ThermostatThermostat terminal Thermostat locationPlease Read this Operating Safety PrecautionsBaffle & exhaust access panel MaintenanceCleaning rod Ash drawer ASH RemovalCleaning Baffle removalVaccum USE Blowers and Pressure Switch Probe Exhaust blower cleaningChimney Cleaning Recommended Maintenance ScheduleTroubleshooting Removal and Replacement of Broken Door GlassStove Shuts OFF and Shows Warning Code P Auger motor has failed Stove Shuts OFF and Displays Warning Code EStove Stops Feeding Pellets and Shows Stove Feeds PELLETS, but will not Ignite Shows Warning CodeAuger Motor Stops Feeding Pellets and Comes Back on Smoke Smell Coming Back Into the HomeStove is Running but Displays Warning Code Message Corresponding Warning Smoke Smell or Soot BUILD-UPElectrical diagram Electrical DiagramComponents left side Components rear Components right sideReplacement Parts Appendix a Horizontal and Vertical Vent ChartAppendix B Indicate Appliance Code Description of the ProblemDescription Drolet Limited Lifetime Warranty