Drolet ECO-35 owner manual Smoke Smell Coming Back Into the Home

Page 23

STOVE STOPS FEEDING PELLETS AND SHOWS

WARNING CODE “H”

Possible Causes:

 

 

 

 

Possible Remedies:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

One of the two L-250 automatic high temperature switch has

 

The L-250 automatic high temperature switches are located on

 

tripped.

 

 

 

 

the top and bottom of the auger housing They send a signal to the

 

 

 

 

 

 

control board if the auger housing overheats. Wait until the

 

 

 

 

 

 

stove cools down AND THEN INSPECT YOUR UNIT.

 

 

 

 

 

 

Improper installation, poor maintenance, or a defective or

 

 

 

 

 

 

missing component may be causing the stove to overheat. Reset

 

 

 

 

 

 

the stove and restart it. Call a technician if you get this code

 

 

 

 

 

 

again.

 

 

 

 

 

 

 

 

*See procedure below to restart the stove.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CODE

BEFORE RESETING

 

 

TO RESET

 

 

 

H1, H2, H3

Heat exchanger and/or exhaust system

 

 

 

 

 

 

 

 

OR H4

is/are clogged. Refer to the owner’s manual

 

 

Press simultaneously for 2 seconds the reset

 

and

 

 

 

for maintenance procedures.

 

 

 

icons .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*** After 3 attempts, reset is no longer possible. Call SBI technical support.

 

 

 

 

 

 

 

 

 

 

 

 

 

STOVE STOPS FEEDING PELLETS AND SHOWS

 

 

 

 

 

 

 

 

 

 

WARNING CODE “d”

 

 

 

 

 

 

 

 

 

 

Possible Causes:

 

 

 

 

Possible Remedies:

 

 

 

 

 

1. The hopper lid has stayed open for more than 3 minutes

 

As a security measure, the auger will stop turning and feeding pellets as

 

 

 

 

 

 

soon as the hopper lid opens. It will resume normal operation as soon as

 

 

 

 

 

 

the hopper lid is closed. However, if the hopper lid stays open for more

 

 

 

 

 

 

than 3 minutes, the unit will stop and a code “d” will appear on the control

 

 

 

 

 

 

board. Close the hopper lid. Reset the unit and start it again.

 

 

 

 

 

 

 

 

 

 

 

SMOKE SMELL COMING BACK INTO THE HOME

 

 

 

 

 

 

 

Possible Causes:

 

 

 

 

Possible Remedies:

 

 

 

 

 

 

1.

There is a leak in the vent pipe system.

 

Inspect all vent pipe connections. Make sure they are sealed with RTV

 

 

 

 

 

 

silicone that has a temperature rating on 500oF or higher. Also, seal joints

 

 

 

 

 

 

with UL-181-AP foil tape.

 

 

 

 

 

 

 

 

 

 

 

 

2.

The gasket on the combustion/exhaust blower housing has

 

Inspect the gasket on the combustion/exhaust blower housing to make

 

gone bad.

 

 

 

 

 

 

 

 

 

sure it is in good shape and replace if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUGER MOTOR STOPS FEEDING PELLETS AND COMES BACK ON

Possible Causes:

1.The auger motor is overheating and tripping the internal temperature shutoff (thermal protector).

Possible Remedies:

Start by emptying the hopper. Follow procedure described in warning code “E” section #6.

23

Image 23
Contents 45266 Model ECO-35 FreestandingIntroduction Register YOU Warranty OnlineSafety Precautions Table of Contents Stove Stops Feeding Pellets and Shows Warning Code d TroubleshootingCorner installation Floor protection Stove InstallationBack wall installation Ventilated crawl space Rear viewFresh air supply Equivalent Vent Lenght EVL Installation ConfigurationsVenting through wall Venting trough wallVertically Into Existing Chimney System Refer to & 10 for basement installationVertically Into Existing Masonry Fireplace Installation Through Side of Masonry ChimneyVenting through masonry chimney Venting through side Masonry chimneyPRE-START-UP Check Lighting ProcedureOperation Proper FuelConvection Blowers Room AIR FAN Unit ControlsOpening Door Damper Control Shutdown ProcedureSafety Features If the Stove Runs OUT of PelletsDamper Operation Damper operationThermostat location Operating the Stove Using a ThermostatThermostat Installation Thermostat terminalPlease Read this Operating Safety PrecautionsASH Removal MaintenanceBaffle & exhaust access panel Cleaning rod Ash drawerVaccum USE CleaningBaffle removal Recommended Maintenance Schedule Exhaust blower cleaningBlowers and Pressure Switch Probe Chimney CleaningStove Shuts OFF and Shows Warning Code P TroubleshootingRemoval and Replacement of Broken Door Glass Auger motor has failed Stove Shuts OFF and Displays Warning Code EStove Stops Feeding Pellets and Shows Stove Feeds PELLETS, but will not Ignite Shows Warning CodeAuger Motor Stops Feeding Pellets and Comes Back on Smoke Smell Coming Back Into the HomeStove is Running but Displays Warning Code Message Corresponding Warning Smoke Smell or Soot BUILD-UPComponents rear Components right side Electrical DiagramElectrical diagram Components left sideReplacement Parts Appendix a Horizontal and Vertical Vent ChartAppendix B Indicate Appliance Code Description of the ProblemDescription Drolet Limited Lifetime Warranty