Enviro C-10450 owner manual High temperature Silicone Male Edge Outer pipe. Push

Page 10

Initial Installation

QUALIFIED INSTALLERS ONLY

HORIZONTAL INSTALLATION:

STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance.

STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented towards the wall or floor, as much out of view as possible.

 

Place a

bead

of

Mil-Pac

on the

�������

 

 

 

 

 

 

 

���

 

outer

edge

of

the

inner

exhaust

 

 

pipe (non-flared end). Place a bead

 

Female

of high temperature

silicone

on the

���

male

edge

of the outer pipe. Push

�������

Locking

the pipe sections completely together,

 

Lugs

 

Sealant

then twist-lock one section clockwise

 

approximately 1⁄4 turn, until the two

 

Male

sections are

fully

locked. The

female

 

locking lugs will not be visible from the

 

Locking

 

Lugs

outside, on black pipe. They may be

 

 

located by examining the inside of the

 

 

female ends as shown in Figure 8.

 

Figure 8: Twist-Lock Connection

 

 

 

 

 

 

Figure 9: Wall Framing Hole for

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal Installation.

(1)Twist-lock procedure: four indentations, located on the female end of the pipes and fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings, by orienting the four pipe indentations so they match and slide into the four entry slots on the male end.

(2)Horizontal runs of vent pipe must be supported every three feet. Wall straps are available for this purpose, also when running horizontal pipe minimum clearances to combustibles must be maintained; 2 inches (5.1 cm) at top, 11⁄2 inches (3.8 cm) at sides, 11⁄2 inches (3.8 cm) at bottom.

STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x 10” (25.4 cm) square hole (refer to Figure 9). The center of the square hole should match the centerline of the horizontal pipe. Cut and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the exterior wall where the vent will be terminated. Refer to Figure 8. If the wall being penetrated is constructed of non-combustible material i.e. masonry or concrete, a 7 inches (17.8 cm) hole is acceptable.

11/4"

 

(3.2cm)

 

Fold strap

Woodscrews

 

here

 

Sheet metal

 

screws

 

 

Wall Thimble

 

Strap

Figure 10: Installing Decorative Wall Thimble.

10

Image 10
Contents EG28 DV S H E R W O O D I N D U S T R I E S L T DFor Your Safety Safety PrecautionsGeneral Table of Contents Vented GAS Fireplace Heater EG28 DV NG/LPG Codes And ApprovalsThis Enviro EG28 DV Fireplace Specifications EG28 Exterior DimensionsInitial Installation Qualified Installers onlyVent restrictor ring Venting Terminals Cannot be Recessed Into a Wall or Siding Vent Pipe Types with Part NumbersCommon Vertical Installation High temperature Silicone Male Edge Outer pipe. Push Installing Horizontal Vent Termination Do not interfere with the structural integrity of the walls Roof Pitch Minimum Height Feet MetersMulti-Story Vent Pipe Installation KIT Components Installation Instructions Wall thimble Assembly of Venting into a Class ‘A’ Chimney EG28 DV Wiring Diagram Then examine the flames, compare the flames to Figure 50% turn down HI-LOW Regulator GAS Line Connection To Test Valve PressuresSecondary Installation Log PlacementLog Placement with Embers Operating Instructions Water Never USE AN Open Flame for Leak TESTING. IfWhat to do if YOU Smell GAS Cleaning Plated Surfaces Routine Maintenance and ServiceCleaning the Inside of the Firebox Opening the DoorTrouble Shooting Problem Possible Cause SolutionParts List Reference Number Part Description Part NumberParts List Parts Diagram Chassis EG 28 Gas Tray and Door Assemblies Warranty To the DistributorInstallation Data Sheet