Enviro C-10450 owner manual Then examine the flames, compare the flames to Figure

Page 20

Initial Installation

REPLACING THE BLOWER:

1. Turn the unit off and remove the log set.

2. Remove the burner tray assembly by removing the screw on either side of the tray, between the front and rear burners. Lift the tray out.

3. Remove the four (4) 5/16” bolts that hold the blower mounting plate to the back firewall. Use a light lubricating oil on screws before removal.

5. Carefully pull the blower assembly into the firebox (see Figure 28). Install the blower onto the mounting bracket (blower outlets pointing through the two holes in the bracket) using the 4 screws provided.

5. Connect wires according to the wiring diagram. If removing the blower, disconnect the blower leads from the harness. Remove the blower.

6. To re-install, check mounting plate gasket if damaged replace with new one and reverse steps 1 through 4. Refer to “Secondary Installation - Installation of Panel Set” and “Secondary Installation - Installation of Log Set and Embers”.

Figure 28: Blower (Fan) Removal.

ADJUSTING THE VENTURIES:

Remove the ash shelf by undoing the screw at each end, pull shelf towards you.

Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.

With along screwdriver rotate spring clips to open or close the shutter to the desired setting.

The venturies allows the amount of air coming into the fireplace to

 

be adjusted in order to accommodate different climates and venting

 

arrangements. Start the pilot and then the burner. Make sure the

 

pilot flame is burning normally and none of the burner ports are

 

plugged. Let the fireplace burn for roughly fifteen minutes and

Figure 29: Blower (Fan) Removal.

then examine the flames, compare the flames to Figure 37.

 

The ideal flame will be blue at the base and light orange above. The flames should be of medium height. If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, the fireplace is getting too much air. Therefore, the venturies should be closed slightly until the correct flames are achieved. Flames that are very orange, with tall, dark, stringy tips, are not getting enough air. Open the venturi until the flames clean up. If the venturi is opened, or closed all the way, and the correct flames cannot be attained, turn off the gas and contact the dealer.

Warning: Incorrect venturi adjustment may lead to improper combustion, which is a safety hazard. Contact the dealer if there is any concern about the venturi adjustment.

20

Image 20
Contents EG28 DV S H E R W O O D I N D U S T R I E S L T DGeneral Safety PrecautionsFor Your Safety Table of Contents This Enviro EG28 DV Fireplace Codes And ApprovalsVented GAS Fireplace Heater EG28 DV NG/LPG Specifications EG28 Exterior DimensionsInitial Installation Qualified Installers onlyVent restrictor ring Venting Terminals Cannot be Recessed Into a Wall or Siding Vent Pipe Types with Part NumbersCommon Vertical Installation High temperature Silicone Male Edge Outer pipe. Push Installing Horizontal Vent Termination Do not interfere with the structural integrity of the walls Roof Pitch Minimum Height Feet MetersMulti-Story Vent Pipe Installation KIT Components Installation Instructions Wall thimble Assembly of Venting into a Class ‘A’ Chimney EG28 DV Wiring Diagram Then examine the flames, compare the flames to Figure 50% turn down HI-LOW Regulator GAS Line Connection To Test Valve PressuresSecondary Installation Log PlacementLog Placement with Embers What to do if YOU Smell GAS Water Never USE AN Open Flame for Leak TESTING. IfOperating Instructions Routine Maintenance and Service Cleaning the Inside of the FireboxCleaning Plated Surfaces Opening the DoorTrouble Shooting Problem Possible Cause SolutionParts List Reference Number Part Description Part NumberParts List Parts Diagram Chassis EG 28 Gas Tray and Door Assemblies Warranty To the DistributorInstallation Data Sheet