Enviro EF-II I Door Glass, Fresh AIR Intake, Inside Firebox, Exhaust Vent, Heat Exchanger Tubes

Page 9

DOOR GLASS

(It is recommended that your dealer replace the glass if broken.)

The door glass is made of 5 mm thick, high temperature PYROCERAMIC The center panel is 229 mm x 330 mm. To replace the glass, unscrew and remove the four glass retainers. Remove the glass and any broken pieces. High temperature fiberglass tape should be used around the glass. Replace the glass, center the glass assembly in the frame, then screw the glass retainers back to the frame. The use of substitute materials is prohibited.

FRESH AIR INTAKE

Inspect periodically to be sure that it is not clogged with any foreign materials.

INSIDE FIREBOX

For bi-weekly clean out, ash may be removed from behind the steel plates by rotating the circular cover to allow vacuuming behind the plates.

Removal of the fire box backing for bi-annual cleaning

-Remove the top baffle.

-Lubricate, and then remove the 7 screws that hold the brick liner in place. Tilt the top of the brick panel towards the firebox opening and pull out to remove from the firebox

-Remove the top rod by first removing the screw that holds it in place, then slide the rod sideways

-Pull the side panels into the center of the firebox, then out

-Pull the center panel out

-Clean all passages thoroughly

Installation of fire box backing:

-Install the side panels in place. Insert center panel, hold the panels in place

-Install the top rod by sliding it into one side panel then across into the other panel. Screw rod in place.

-Re-install steel brick liner and screw into place.

-Replace top baffle

EXHAUST VENT

Soot and Flyash: Formation and Need for Removal: - The products of combustion will contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at least once every year or after two tons of pellets to determine if cleaning is necessary. We recommend contacting your dealer for professional cleaning. To remove dust from the vent pipe, tap lightly on the pipe to dislodge any loose ash. Open the bottom of the ”T” to dump the ash, then vacuum as much of the ash out of the vent pipe as possible.

HEAT EXCHANGER TUBES

The cleaning rod is to be pulled back and forth a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fly ash that may have collected on the heat exchanger tubes. As different types of pellets produce different amounts of ash, cleaning of the tubes should be done on a regular basis to enable the unit to run efficiently.

POST SEASON CLEAN-UP

Once you are finished using the pellet appliance for the season, unplug the stove for added electrical protection. It is very important that the stove be cleaned and serviced as stated above. (See Section Areas of Routine Inspection)

9

Image 9
Contents EF-ΙΙ Installation Envirofire Installation ManualUSE of Cordwood is Prohibited by LAW Important Safety DataPellet Quality is Important Please Read the Following Automatic Safety Features of Your Pellet Stove Turning Your Pellet Appliance OFF HOW to Start Your Pellet ApplianceOn LOW SLIDER/DAMPER Installation /OPERATIONS InstructionsPush all Way On HighASH PAN and Door Gaskets Areas for Routine InspectionFreestanding ASH PAN Blower MechanismsDoor Glass Post Season CLEAN-UPFresh AIR Intake Inside FireboxElectrical Component Functions 11 F 49C- N/O Temperature Sensor Shut Down Sensor 10 F 71C Temperature Sensor12 F 49C-N/C Temperature Sensor Igniter Shut Down Sensor Vacuum SwitchVent Termination Requirements Deciding Where to Locate Your Pellet ApplianceRemoving Your NEW Stove from IT’S Pallet DimensionsFireplace Insert Size Masonry Fireplace Insert INSTALLATION, Model FPIAssembling the Face Plate for the FPI and BIH Models Built in Heater Clearances to Combustibles Recommended Framing for Built in HeaterClearance to Combustibles Freestanding Clearances to CombustiblesInstallation Keyholes Model FS Freestanding InstallationHorizontal Exhaust Through the Wall Through Wall Installation Inside Vertical INSTALLATION, Model FS Outside Vertical Pipe Installation Outside Fresh AIR Connections Mobile Home InstallationTroubleshooting TroubleshootingDo not Stove will not startExhaust blower will not function normally Stove will not function in the Auto mode when hotConvection blower will not function normally Auger motor will not function normallyStove will not shut down Stove keeps going outIgnitor will not function normally Wiring Diagram Parts List EF-146 EF-079July Exploded Components To the Dealer WarrantyTo the Distributor For the do-it-yourself Individual

EF-II I specifications

The Enviro EF-II I represents a significant advancement in eco-friendly filtration technology, designed to meet the demands of a rapidly changing environment. Focusing on high-efficiency performance and sustainability, the EF-II I offers an innovative approach to air and water purification, making it a vital tool for both residential and commercial applications.

One of the key features of the Enviro EF-II I is its multi-stage filtration system. This system incorporates pre-filters, HEPA filters, and activated carbon filters, which work in concert to capture a wide range of pollutants, allergens, and harmful particles. The pre-filters are designed to trap larger particles, while HEPA technology ensures that up to 99.97% of airborne contaminants down to 0.3 microns are effectively removed. The activated carbon filter then targets volatile organic compounds (VOCs) and odors, resulting in cleaner, fresher air.

In addition to its robust filtration capabilities, the EF-II I is equipped with advanced sensing technology. The built-in smart sensors continuously monitor air quality and provide real-time feedback to users. The unit can adjust its performance based on current air conditions, optimizing energy use and enhancing overall efficiency. This responsive technology not only ensures a healthier indoor environment but also contributes to energy savings.

The design of the Enviro EF-II I emphasizes user-friendliness. An intuitive interface with easy-to-read displays allows users to monitor filter life, check air quality levels, and adjust settings with minimal hassle. Moreover, a smart app compatibility feature means users can control the device remotely, receiving alerts and notifications straight to their smartphones.

Another notable characteristic of the EF-II I is its eco-friendly construction. Made from sustainable materials, the device is built to last while minimizing environmental impact. The filters themselves are replaceable and recyclable, aligning with a commitment to reduce waste.

Noise reduction technology ensures that the EF-II I operates quietly, making it suitable for various environments, from homes to offices. This emphasis on a peaceful atmosphere, combined with the effectiveness of its filtration system, underscores the Enviro EF-II I's position as a leader in air and water purification technology.

In summary, the Enviro EF-II I merges state-of-the-art filtration technology with smart features and sustainable design, making it an essential solution for those seeking cleaner air and healthier living spaces. Its combination of efficiency, user-friendly operation, and environmental consciousness sets a new standard in the industry, catering to the needs of a modern, health-focused society.