Enviro EF-II I technical manual Important Safety Data, USE of Cordwood is Prohibited by LAW

Page 3

IMPORTANT SAFETY DATA

Please read this entire manual before installation and use of this pellet fuel burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death.

CAUTION: DO NOT CONNECT OT ANY AIR DISTRIBUTION DUCT OR SYSTEM;

DO NOT BURN GARBAGE OR FLAMABLE FLUIDS SUCH AS GASOLINE, NAPTHA OR ENGINE OIL;

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.

Contact local building officials about restrictions and installation inspection requirements in your area.

The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure, it is very important to ensure that the exhaust system be sealed and airtight.

The use of grates or other methods of supporting the fuel is not permitted.

This unit is designed to burn pelletized wood fuel only. Do not use any other type of fuel, this will void any warranties stated in this manual.

THE USE OF CORDWOOD IS PROHIBITED BY LAW.

Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by adjusting the slide damper located on the left side of the stove.

It is advisable to clean the exhaust vent bi-annually or every two tons of pellets.

The grounded electrical cord should be connected to a standard 115 volts, 60-hertz electrical outlet. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges. This unit’s maximum power requirement is 450 watts (3.91 Amps).

Soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn (black tipped, lazy orange flames).

When installing the stove in a mobile home, it must be electrically grounded to the steel chassis of the home and bolted to the floor. Make sure that the structural integrity of the home is maintained.

Be sure to maintain the structural integrity of home when passing a vent through walls, ceilings, or roofs.

The ash pan and viewing door must be locked securely for proper and safe operation of the pellet stove.

If you have any questions with regards to your stove or the above-mentioned information, please feel free to contact your local dealer for further clarification and comments.

Since Sherwood Industries Ltd. has no control over the installation of your stove, we grant no warranty implied or stated for the installation or maintenance of your stove, therefore, Sherwood Industries Ltd. assumes no responsibility for any consequential damage.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

3

Image 3
Contents EF-ΙΙ Installation Envirofire Installation ManualUSE of Cordwood is Prohibited by LAW Important Safety DataPellet Quality is Important Please Read the Following Automatic Safety Features of Your Pellet Stove Turning Your Pellet Appliance OFF HOW to Start Your Pellet ApplianceOn High SLIDER/DAMPER Installation /OPERATIONS InstructionsOn LOW Push all WayBlower Mechanisms Areas for Routine InspectionASH PAN and Door Gaskets Freestanding ASH PANInside Firebox Post Season CLEAN-UPDoor Glass Fresh AIR IntakeElectrical Component Functions Vacuum Switch 10 F 71C Temperature Sensor11 F 49C- N/O Temperature Sensor Shut Down Sensor 12 F 49C-N/C Temperature Sensor Igniter Shut Down SensorVent Termination Requirements Deciding Where to Locate Your Pellet ApplianceRemoving Your NEW Stove from IT’S Pallet DimensionsFireplace Insert Size Masonry Fireplace Insert INSTALLATION, Model FPIAssembling the Face Plate for the FPI and BIH Models Built in Heater Clearances to Combustibles Recommended Framing for Built in HeaterClearance to Combustibles Freestanding Clearances to CombustiblesInstallation Keyholes Model FS Freestanding InstallationHorizontal Exhaust Through the Wall Through Wall Installation Inside Vertical INSTALLATION, Model FS Outside Vertical Pipe Installation Outside Fresh AIR Connections Mobile Home InstallationStove will not start TroubleshootingTroubleshooting Do notAuger motor will not function normally Stove will not function in the Auto mode when hotExhaust blower will not function normally Convection blower will not function normallyStove will not shut down Stove keeps going outIgnitor will not function normally Wiring Diagram Parts List EF-146 EF-079July Exploded Components For the do-it-yourself Individual WarrantyTo the Dealer To the Distributor

EF-II I specifications

The Enviro EF-II I represents a significant advancement in eco-friendly filtration technology, designed to meet the demands of a rapidly changing environment. Focusing on high-efficiency performance and sustainability, the EF-II I offers an innovative approach to air and water purification, making it a vital tool for both residential and commercial applications.

One of the key features of the Enviro EF-II I is its multi-stage filtration system. This system incorporates pre-filters, HEPA filters, and activated carbon filters, which work in concert to capture a wide range of pollutants, allergens, and harmful particles. The pre-filters are designed to trap larger particles, while HEPA technology ensures that up to 99.97% of airborne contaminants down to 0.3 microns are effectively removed. The activated carbon filter then targets volatile organic compounds (VOCs) and odors, resulting in cleaner, fresher air.

In addition to its robust filtration capabilities, the EF-II I is equipped with advanced sensing technology. The built-in smart sensors continuously monitor air quality and provide real-time feedback to users. The unit can adjust its performance based on current air conditions, optimizing energy use and enhancing overall efficiency. This responsive technology not only ensures a healthier indoor environment but also contributes to energy savings.

The design of the Enviro EF-II I emphasizes user-friendliness. An intuitive interface with easy-to-read displays allows users to monitor filter life, check air quality levels, and adjust settings with minimal hassle. Moreover, a smart app compatibility feature means users can control the device remotely, receiving alerts and notifications straight to their smartphones.

Another notable characteristic of the EF-II I is its eco-friendly construction. Made from sustainable materials, the device is built to last while minimizing environmental impact. The filters themselves are replaceable and recyclable, aligning with a commitment to reduce waste.

Noise reduction technology ensures that the EF-II I operates quietly, making it suitable for various environments, from homes to offices. This emphasis on a peaceful atmosphere, combined with the effectiveness of its filtration system, underscores the Enviro EF-II I's position as a leader in air and water purification technology.

In summary, the Enviro EF-II I merges state-of-the-art filtration technology with smart features and sustainable design, making it an essential solution for those seeking cleaner air and healthier living spaces. Its combination of efficiency, user-friendly operation, and environmental consciousness sets a new standard in the industry, catering to the needs of a modern, health-focused society.