VENT TERMINATION REQUIREMENTS:

IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Table 1: Use in conjunction with Figure 15 for allowable exterior vent termination locations.

Letter

Minimum Clearance

Description

 

 

 

A

24 in (61 cm)

Above grass, top of plants, wood, or any other combustible materials.

 

 

 

B

48 in (122 cm)

From beside/below any door or window that may be opened.

 

 

 

C

24 in (61 cm)

From above any door or window that may be opened.

 

 

 

D

24 in (61 cm)

To any adjacent building, fences and protruding parts of the structure.

 

 

 

E

24 in (61 cm)

Below any eave or roof overhang

 

 

 

F

12 in (30 cm)

To outside corner.

 

 

 

G

12 in (30 cm)

To inside corner, combustible wall (vertical and horizontal terminations).

 

 

 

H

3 ft (91 cm) within a height of 15 ft (4.5

To each side of center line extended above natural gas or propane meter/regulator assembly or

 

m) above the meter/regulator assembly

mechanical vent.

 

 

 

I

3 ft (91 cm)

From any forced air intake of other appliance

 

 

 

J

12 in (30 cm)

Clearance to non-mechanical air supply inlet to building, or the combustion air inlet to any appliance.

 

 

 

K

24 in (61 cm)

Clearance above roof line for vertical terminations.

 

 

 

L

7 ft (2.13 m)

Clearance above paved sidewalk or paved driveway located on public property.

 

 

 

1.Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow walkway, closely fenced area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, covered breezeway, etc.

2.Vent surfaces can

 

 

 

 

 

 

K

G

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

D

F

 

Opens

B

C

G

 

 

 

 

G

 

 

Opens

 

 

 

 

 

 

 

 

 

 

 

B

 

A

 

I

Opens

L

 

 

 

 

 

 

 

 

 

Termination Cap

G

Gas Meter

H

 

 

 

Air Supply Inlet

Restriction Zone

 

 

 

 

 

 

(Termination not allowed)

 

Figure 15: Use in conjunction with Table 1 for allowable exterior vent termination locations.

become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required.

3.Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be installed outside when the appliance is vented directly through a wall, to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure. This will keep exhaust from causing a nuisance or hazard from exposing people or shrubs to high temperatures. In any case, the safest and preferred venting method is to extend the vent through the roof vertically.

4.Distance from the bottom of the termination and grade is 12” (30 cm) minimum. This is conditional upon the plants and nature of grade surface. The exhaust gases are hot enough to ignite grass, plants and shrubs located in the vicinity of termination. The grade surface must not be lawn.

5.If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since these factors are beyond the control of Sherwood Industries Ltd, we grant no guarantee against such incidents.

6.When installing an FPI the chimney must be fully lined. Unless the chimney’s inside diameter is less than 6” (15 cm) around or has a cross section area of 28 inches² (180.6 cm²), we strongly recommend lining all masonry chimneys.

NOTE: Venting terminals shall not be recessed into walls or siding.

15

Image 15
Contents EF2 Table of Contents Introduction I. Pellet StandardsStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Reasons WHY the Unit Overheated Operating InstructionsSpecial Notes Special Notes Inside Firebox 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Burn POT and Liner 2-3 daysNot Place Unburned or RAW Pellet Fuel in ASH PAN Freestanding ASH PANFireplace Insert and BUILT-IN Heater ASH PAN Post Season CLEAN-UP Cleaning Plated SurfacesBrick Panel Screws to take out to remove stove from pallet InstallationDimensions of EF2 Freestanding Minimum Alcove width Inches 91 cm Minimum Alcove height EF2 Built-In Heater recommended Framing Or from the outside of the pedestal for the FPI or BIHVent surfaces can Exhaust Freestanding Fireplace Insert Built-In HeaterFresh AIR Intake Fresh Air Intake Unit on it Locate the center of the exhaust Is the recommended installation set up Inside Vertical Installation Install the hearth pad Freestanding hearth mount installation overview Connect a tee or 90 degree This unit includes a 3 75 mm pedestal Corner Brackets Side surround panel swings forward RemovalTroubleshooting Stove will not startStove will not light Stove will not function in the Auto mode when hot Exhaust motor will not function normallyConvection blower will not function normally Auger motor will not function normally Stove keeps going out Dial-a-fire has no effect on the firePotentiometer Readings Stove will not shut offWiring Diagram Parts List Fireplace Insert Stove Top Parts List Parts List Options ComponentsDPartsiagram Parts Diagram Steel Warranty To the DealerTo the Distributor Name of Owner Address Installation Data Sheet

EF-119 specifications

The Enviro EF-119 is an innovative, environmentally friendly vehicle that has garnered attention for its advanced technology and impressive performance characteristics. Designed with sustainability in mind, the EF-119 incorporates cutting-edge features that make it a standout choice in the green vehicle market.

One of the main highlights of the Enviro EF-119 is its electric powertrain. The vehicle is equipped with a high-capacity lithium-ion battery that offers a range of up to 300 miles on a single charge, making it ideal for both urban commuting and longer journeys. The EF-119 also features fast charging capabilities, allowing drivers to recharge their batteries to 80% in just under 30 minutes with compatible charging stations, significantly reducing downtime during travel.

In terms of design, the EF-119 boasts a sleek, aerodynamic shape that not only enhances its visual appeal but also improves energy efficiency. The vehicle's lightweight chassis is constructed from advanced composite materials, reducing overall weight while maintaining structural integrity. This design decision contributes to lower energy consumption and improved handling on the road.

The EF-119 comes equipped with an array of smart technologies that enhance the driving experience. An intuitive infotainment system offers seamless connectivity with smartphones and other devices, allowing drivers to access navigation, music, and communication apps effortlessly. Additionally, the vehicle includes advanced safety features, such as adaptive cruise control, lane-keeping assist, and a comprehensive suite of sensors that provide real-time data on the vehicle's surroundings, ensuring a safe and comfortable ride.

Another notable characteristic of the Enviro EF-119 is its regenerative braking system. This technology captures energy typically lost during braking and redirects it back into the battery, enhancing overall efficiency and extending the vehicle's range. The result is a more sustainable driving experience that reduces wear on traditional braking systems.

Overall, the Enviro EF-119 represents a significant step forward in the evolution of electric vehicles. With its impressive range, advanced safety features, and commitment to sustainability, it meets the needs of modern drivers who prioritize eco-friendly transportation without compromising on performance or style. As the automotive industry shifts towards greener alternatives, the EF-119 stands out as a leading choice for environmentally conscious consumers seeking innovation and excellence.