Enviro EF-IV I EXHAUST/COMBUSTION Blower, Auger Motor and Auger, Timing Control Module

Page 11

11

8

9

5

10

6.EXHAUST/COMBUSTION BLOWER

7

14

This variable speed fan (mounted on the left side of the stove) is responsible for drawing the outside fresh air into the combustion chamber for burning. The hot air then continues to be drawn over the heat exchanger tubes and into the exhaust channel. It is then pushed out through the exhaust system. A motor speed controller tied in with the Dial-A-Fire controls the speed of the blower.

7.AUGER MOTOR AND AUGER

The 1 rpm auger motor is responsible for turning the auger, which in turn transports pellets to be dropped into the burn pot. The auger motor’s control is handled by the timing control module and Dial-A-Fire.

8.EXHAUST/COMBUSTION PHASE CONTROLLER (BLOWER SPEED CONTROL MODULE)

The phase controller supplies an adjustable voltage to the combustion blower. The voltage controls the blower’s speed. The module is controlled by a potentiometer in the Dial a Fire. As the feed rate is increased, the blower’s speed is increased proportionally.

9.TIMING CONTROL MODULE

The timing control module is mounted in the middle, on the right rear pillar of the stove. The module controls the switching of power to the auger motor. The module’s switching duty cycle is controlled by the dial-a-fire.

10.START-UP TIMER

This 15-minute one-shot timer, bypasses the 120°F (49°C) temperature sensor allowing the stove to operate when cold. The timing cycle is initiated by pressing the start-up switch. The 15-minute timer is located right under the timing control module on the right side pillar. This unit is also responsible for initiating the ignition cycle.

11.200°F (93°C) MANUAL RESET TEMPERATURE SENSOR

This sensor (located on the right side firewall) has a red push button located in its center. This is a safety device. In the event that the convection blower fails, this sensor will overheat and shut off power to the auger motor.

11

Image 11
Contents EF-IV Operation Envirofire Installation ManualUSE of Cordwood is Prohibited by LAW Important Safety DataI. Pellet Standards Pellet Quality is IMPORTANT, Please Read FollowingAutomatic Safety Features of Your Pellet Stove Turning Your Pellet Stove OFF HOW to Start and Operate Your Pellet ApplianceSpecial Notes SLIDER/DAMPER Installation InstructionsClip on Door Installation Freestanding ASH PAN # 1 see Areas for Routine InspectionASH PAN and Door Gaskets Burn POT Liner Igniter Tube Fresh AIR Insert ASH RemovalInstallation of fire box backing Electrical Component Functions Auger Motor and Auger START-UP Timer11 F 93C Manual Reset Temperature Sensor EXHAUST/COMBUSTION BlowerVacuum Switch 12 F 71C Temperature Sensor13 F 49C N/O Temperature Sensor SHUT-DOWN Sensor 14 F 49C N/C Temperature Sensor Ignitor Shut Down SensorVent Termination Requirements Deciding Where to Locate Your Pellet ApplianceRemoving Your NEW Stove from IT’S Pallet Fireplace DimensionsClearance to Combustibles Masonry Fireplace Insert INSTALLATION, Model FPIStandard 40 X 27 7/8 FPI Pedestal InstallationAssembling the Face Plate for the FPI Model Clearance to Combustibles Freestanding INSTALLATION, Model FSInstall Four Screws Here Freestanding Pedestal InstallationAssembly Horizontal Exhaust Through the Wall Through Wall Installation Inside Vertical Through the Roof Installation Outside Vertical Pipe Installation Outside Fresh AIR Connections Mobile Home InstallationStove will not start TroubleshootingIgniter- the pellets will not light Stove will not operate when hotExhaust motor will not function normally Convection blower will not function normallyDial-a-fire has no effect on the fire Auger motor will not function normallyStove keeps going out Stove will not shut downWiring Diagram Back Grill Parts ListComponents Exploded EF 4Exploded Steel Components To the Distributor WarrantyFor the do-it-yourself Individual To the Dealer

EF-IV I specifications

The Enviro EF-IV I is an innovative next-generation environmental control unit designed to meet the diverse needs of modern aviation. With a strong focus on efficiency, reliability, and sustainability, the EF-IV I has garnered attention for its cutting-edge features and advanced technologies that elevate cabin comfort while reducing the ecological footprint.

One of the most notable features of the Enviro EF-IV I is its hybrid cooling technology. By integrating both conventional and thermal energy systems, the unit can operate with higher efficiency across various conditions. This technology allows for significant energy savings while maintaining optimal temperature control in the cabin, making it an ideal choice for eco-conscious airlines looking to minimize operational costs.

The EF-IV I boasts a sophisticated air filtration system that enhances cabin air quality. Utilizing advanced HEPA filters and multi-layer filtration processes, this unit captures airborne particles and contaminants, ensuring that passengers breathe clean and fresh air during their flights. Its intelligent monitoring system continuously assesses air quality parameters and adjusts filtration performance in real-time, providing a proactive approach to maintaining a healthy cabin environment.

In terms of user interface, the EF-IV I is equipped with an intuitive digital control panel that allows crew members to easily monitor and adjust settings. This interface features an interactive display providing valuable data on system performance, energy consumption, and maintenance schedules, empowering operators with real-time insights that contribute to seamless operations.

The compact design of the EF-IV I facilitates easier installation and integration into existing aircraft systems, making it a flexible choice for both new aircraft and retrofitting older models. Its lightweight materials and streamlined construction not only minimize weight and improve fuel efficiency but also enhance overall durability and reduce maintenance requirements.

Finally, the Enviro EF-IV I is built with sustainability in mind. Its materials and manufacturing processes are compliant with international environmental standards, ensuring that the unit adheres to stringent regulations and contributes positively to the overall environmental impact of aviation.

With its advanced features, sustainability focus, and commitment to enhancing passenger experience, the Enviro EF-IV I represents a significant step forward in environmental control technology for the aviation industry. It is a testament to the ongoing innovation and dedication to creating a more sustainable future in air travel.