Enviro EF-IV I SLIDER/DAMPER Installation Instructions, Clip on Door Installation, Special Notes

Page 7

SLIDER/DAMPER INSTALLATION INSTRUCTIONS

This is used to regulate the airflow through the pellet stove.

A Qualified Service Technician or Installer should set the Slider Damper.

The Slider Damper is pre set from the factory. The slider damper will be set and held in place with a 5/16” hex head screw. This screw will be tightened in the middle of the slot located in the slider damper plate.

The slider damper is located behind the left side panel. To open the left side panel, undo the one screw located in the upper front corner of the cabinet side

The combustion exhaust blower is a variable speed blower controlled by the heat output knob,(Dial a Fire). This blower will decrease the vacuum pressure inside the stove and as the heat output knob is turned up. The vacuum pressure inside the firebox will increase as the combustion exhaust blower increases in speed.

SPECIAL NOTES:

Pellet quality is a major factor in how the Pellet stove will operate. If the Pellets have a high moisture content or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers. (hard ash build-up)

If the fire should happen to go out and the Dial A Fire has been set on the lowest setting, the Slider Damper should be pushed in slightly decreasing the air in the firebox.

If after long periods of burning the fire builds up and over flows the burn pot or there is a build up of clinkers This would be a sign that the pellet quality is poor and the slider damper must be pulled out to compensate.

Pulling the slider damper out gives the fire more air.

The easiest way to make sure that an efficient flame is achieved is to see the characteristics of the fire.

A tall and lazy flame with dark orange tips requires more air – Open slider / damper up.

A short and brisk flame, like a blowtorch, has too much air – Close slider / damper down.

If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame then the air is set for proper operation.

CLIP ON DOOR INSTALLATION

1.Unlatch door and swing open, remove door form unit.

2.Place door on a soft flat surface and remove the (4) screws (2 on each side) that hold the side trim pieces to the door.

3.Undo all four screws that hold the outer clip on the door.

4.Install the new ( GOLD or NICKEL) clip on door using the four screws to fasten to the door.

5.Reinstall the side trim pieces using the screws that were removed from step 1.

6.Reinstall the door on the unit and latch with the handle provided.

Side trim

 

pieces

 

2 screws per

 

Inner door

side

 

Clip on door (GOLD

 

or NICKEL)

7

Image 7
Contents EF-IV Operation Envirofire Installation ManualUSE of Cordwood is Prohibited by LAW Important Safety DataI. Pellet Standards Pellet Quality is IMPORTANT, Please Read FollowingAutomatic Safety Features of Your Pellet Stove Turning Your Pellet Stove OFF HOW to Start and Operate Your Pellet ApplianceClip on Door Installation SLIDER/DAMPER Installation InstructionsSpecial Notes Freestanding ASH PAN # 1 see Areas for Routine InspectionASH PAN and Door Gaskets Burn POT Liner Igniter Tube Fresh AIR Insert ASH RemovalInstallation of fire box backing Electrical Component Functions Auger Motor and Auger START-UP Timer11 F 93C Manual Reset Temperature Sensor EXHAUST/COMBUSTION BlowerVacuum Switch 12 F 71C Temperature Sensor13 F 49C N/O Temperature Sensor SHUT-DOWN Sensor 14 F 49C N/C Temperature Sensor Ignitor Shut Down SensorVent Termination Requirements Deciding Where to Locate Your Pellet ApplianceRemoving Your NEW Stove from IT’S Pallet Fireplace DimensionsClearance to Combustibles Masonry Fireplace Insert INSTALLATION, Model FPIAssembling the Face Plate for the FPI Model FPI Pedestal InstallationStandard 40 X 27 7/8 Clearance to Combustibles Freestanding INSTALLATION, Model FSAssembly Freestanding Pedestal InstallationInstall Four Screws Here Horizontal Exhaust Through the Wall Through Wall Installation Inside Vertical Through the Roof Installation Outside Vertical Pipe Installation Outside Fresh AIR Connections Mobile Home InstallationStove will not start TroubleshootingIgniter- the pellets will not light Stove will not operate when hotExhaust motor will not function normally Convection blower will not function normallyDial-a-fire has no effect on the fire Auger motor will not function normallyStove keeps going out Stove will not shut downWiring Diagram Back Grill Parts ListComponents Exploded EF 4Exploded Steel Components To the Distributor WarrantyFor the do-it-yourself Individual To the Dealer

EF-IV I specifications

The Enviro EF-IV I is an innovative next-generation environmental control unit designed to meet the diverse needs of modern aviation. With a strong focus on efficiency, reliability, and sustainability, the EF-IV I has garnered attention for its cutting-edge features and advanced technologies that elevate cabin comfort while reducing the ecological footprint.

One of the most notable features of the Enviro EF-IV I is its hybrid cooling technology. By integrating both conventional and thermal energy systems, the unit can operate with higher efficiency across various conditions. This technology allows for significant energy savings while maintaining optimal temperature control in the cabin, making it an ideal choice for eco-conscious airlines looking to minimize operational costs.

The EF-IV I boasts a sophisticated air filtration system that enhances cabin air quality. Utilizing advanced HEPA filters and multi-layer filtration processes, this unit captures airborne particles and contaminants, ensuring that passengers breathe clean and fresh air during their flights. Its intelligent monitoring system continuously assesses air quality parameters and adjusts filtration performance in real-time, providing a proactive approach to maintaining a healthy cabin environment.

In terms of user interface, the EF-IV I is equipped with an intuitive digital control panel that allows crew members to easily monitor and adjust settings. This interface features an interactive display providing valuable data on system performance, energy consumption, and maintenance schedules, empowering operators with real-time insights that contribute to seamless operations.

The compact design of the EF-IV I facilitates easier installation and integration into existing aircraft systems, making it a flexible choice for both new aircraft and retrofitting older models. Its lightweight materials and streamlined construction not only minimize weight and improve fuel efficiency but also enhance overall durability and reduce maintenance requirements.

Finally, the Enviro EF-IV I is built with sustainability in mind. Its materials and manufacturing processes are compliant with international environmental standards, ensuring that the unit adheres to stringent regulations and contributes positively to the overall environmental impact of aviation.

With its advanced features, sustainability focus, and commitment to enhancing passenger experience, the Enviro EF-IV I represents a significant step forward in environmental control technology for the aviation industry. It is a testament to the ongoing innovation and dedication to creating a more sustainable future in air travel.