Enviro EF-IV I technical manual Exploded Steel Components

Page 31

FS STOVE TOP

EF4I-111

BACK GRILL

EF4i-097

STOVE TOP

HANDLE

FS RIGHT

CABINET

SIDE

EF4i-143

 

 

 

 

 

 

 

STAINLESS

 

 

 

 

 

 

 

 

 

 

 

 

BURN POT

 

 

 

 

CONTROL

 

 

 

 

 

LINER

 

FIREBOX

 

PANEL w

 

 

 

 

EF4i-024

 

LINER TOP

 

DECAL

 

 

 

EF4i-053

 

 

 

 

BAFFLE

 

 

 

 

 

 

 

 

 

EF4i-066

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGNITION

 

 

 

 

BURN POT

 

 

 

 

 

EF4i-021

 

FS LEFT

CABINET

SIDE

EF4i-142

FS

PEDESTAL (ASH PAN TYPE)

EF4i-139

VACUUM

PORT

COVER

ASH PAN W/

 

LATCH

ASH PAN

EF4i-105

 

LATCH

 

 

EF4i-060

FIREBOX

LINER W/

INSULATION

EF4i-047

STEEL BRICK

LINING

EF4i-130

GLASS SET

EF4i-062

GOLD DOOR COMPLETE

FRONT

GRILL

EF4i-123

 

DOOR LATCH

DOOR LATCH

GLASS

AND HINGE

COVERS

WITH BOLT

RETAINERS

EF4i-096

EF4i-029

 

 

GLASS

 

 

EXTRUSIONS

 

 

DOOR

 

 

HANDLE

 

 

(WOODEN)

EF4i-028

INNER

GOLD OR PAINTED

EF 4 I

EXPLODED (STEEL COMPONENTS)

Page 2 of 2

JULY 2001

EF4i-092

PAINTED DOOR COMPLETE

31 EF4i-094

DOOR (B)

OUTER DOOR (A + B)

 

EF4i-095 PAINTED

 

EF4i-093 GOLD

Image 31
Contents EF-IV Operation Envirofire Installation ManualUSE of Cordwood is Prohibited by LAW Important Safety DataI. Pellet Standards Pellet Quality is IMPORTANT, Please Read FollowingAutomatic Safety Features of Your Pellet Stove Turning Your Pellet Stove OFF HOW to Start and Operate Your Pellet ApplianceClip on Door Installation SLIDER/DAMPER Installation InstructionsSpecial Notes Freestanding ASH PAN # 1 see Areas for Routine InspectionASH PAN and Door Gaskets Burn POT Liner Igniter Tube Fresh AIR Insert ASH RemovalInstallation of fire box backing Electrical Component Functions Auger Motor and Auger START-UP Timer11 F 93C Manual Reset Temperature Sensor EXHAUST/COMBUSTION BlowerVacuum Switch 12 F 71C Temperature Sensor13 F 49C N/O Temperature Sensor SHUT-DOWN Sensor 14 F 49C N/C Temperature Sensor Ignitor Shut Down SensorVent Termination Requirements Deciding Where to Locate Your Pellet ApplianceRemoving Your NEW Stove from IT’S Pallet Fireplace DimensionsClearance to Combustibles Masonry Fireplace Insert INSTALLATION, Model FPIAssembling the Face Plate for the FPI Model FPI Pedestal InstallationStandard 40 X 27 7/8 Clearance to Combustibles Freestanding INSTALLATION, Model FSAssembly Freestanding Pedestal InstallationInstall Four Screws Here Horizontal Exhaust Through the Wall Through Wall Installation Inside Vertical Through the Roof Installation Outside Vertical Pipe Installation Outside Fresh AIR Connections Mobile Home InstallationStove will not start TroubleshootingIgniter- the pellets will not light Stove will not operate when hotExhaust motor will not function normally Convection blower will not function normallyDial-a-fire has no effect on the fire Auger motor will not function normallyStove keeps going out Stove will not shut downWiring Diagram Back Grill Parts ListComponents Exploded EF 4Exploded Steel Components To the Distributor WarrantyFor the do-it-yourself Individual To the Dealer

EF-IV I specifications

The Enviro EF-IV I is an innovative next-generation environmental control unit designed to meet the diverse needs of modern aviation. With a strong focus on efficiency, reliability, and sustainability, the EF-IV I has garnered attention for its cutting-edge features and advanced technologies that elevate cabin comfort while reducing the ecological footprint.

One of the most notable features of the Enviro EF-IV I is its hybrid cooling technology. By integrating both conventional and thermal energy systems, the unit can operate with higher efficiency across various conditions. This technology allows for significant energy savings while maintaining optimal temperature control in the cabin, making it an ideal choice for eco-conscious airlines looking to minimize operational costs.

The EF-IV I boasts a sophisticated air filtration system that enhances cabin air quality. Utilizing advanced HEPA filters and multi-layer filtration processes, this unit captures airborne particles and contaminants, ensuring that passengers breathe clean and fresh air during their flights. Its intelligent monitoring system continuously assesses air quality parameters and adjusts filtration performance in real-time, providing a proactive approach to maintaining a healthy cabin environment.

In terms of user interface, the EF-IV I is equipped with an intuitive digital control panel that allows crew members to easily monitor and adjust settings. This interface features an interactive display providing valuable data on system performance, energy consumption, and maintenance schedules, empowering operators with real-time insights that contribute to seamless operations.

The compact design of the EF-IV I facilitates easier installation and integration into existing aircraft systems, making it a flexible choice for both new aircraft and retrofitting older models. Its lightweight materials and streamlined construction not only minimize weight and improve fuel efficiency but also enhance overall durability and reduce maintenance requirements.

Finally, the Enviro EF-IV I is built with sustainability in mind. Its materials and manufacturing processes are compliant with international environmental standards, ensuring that the unit adheres to stringent regulations and contributes positively to the overall environmental impact of aviation.

With its advanced features, sustainability focus, and commitment to enhancing passenger experience, the Enviro EF-IV I represents a significant step forward in environmental control technology for the aviation industry. It is a testament to the ongoing innovation and dedication to creating a more sustainable future in air travel.