Enviro EF-IV I technical manual Troubleshooting, Stove will not start

Page 24

TROUBLESHOOTING:

DO NOT:

-Hold the start-up switch down, this is a momentary contact switch and can be damaged if held down too long.

-Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures.

-Remove any screws in the firebox without first lubricating them with penetrating oil.

What to do if:

1.The stove will not start

2.The stove will not operate when hot

3.The exhaust blower will not function normally

4.The convection blower will not function normally

5.Igniter : The pellets will not light.

6.The auger motor does not function normally

7.The Dial-A-Fire has no effect on the fire

8.The stove will not shut off

9.The stove keeps going out

*NOTE: All troubleshooting procedures should be carried out by qualified technicians or installers.

1.The stove will not start

-Make sure the stove is plugged in and the wall outlet is supplying power.

-Push the Start-up switch, if the stove fails to start, unplug the unit and open the hinged side panels (held tight with one screw at the top, front).

-With the stove unplugged, examine all connections. Make sure they are firmly connected and that there are no exposed wires touching the stove (except the chassis ground wire).

-Check the continuity and placement of connections against the diagram in the back of this manual.

-Ensure that the connections to the (15) minute start-up timer are correct.

-Attempt to bypass the switch by inserting a jumper wire between the red and white wires that attach to the switch. Plug the stove back in. If the stove starts, replace the switch.

-If this fails, replace the (15) minute start-up timer.

24

Image 24
Contents EF-IV Envirofire Installation Manual OperationImportant Safety Data USE of Cordwood is Prohibited by LAWPellet Quality is IMPORTANT, Please Read Following I. Pellet StandardsAutomatic Safety Features of Your Pellet Stove HOW to Start and Operate Your Pellet Appliance Turning Your Pellet Stove OFFSLIDER/DAMPER Installation Instructions Clip on Door InstallationSpecial Notes Areas for Routine Inspection ASH PAN and Door GasketsBurn POT Liner Igniter Tube Fresh AIR Insert ASH Removal Freestanding ASH PAN # 1 seeInstallation of fire box backing Electrical Component Functions START-UP Timer 11 F 93C Manual Reset Temperature SensorEXHAUST/COMBUSTION Blower Auger Motor and Auger12 F 71C Temperature Sensor 13 F 49C N/O Temperature Sensor SHUT-DOWN Sensor14 F 49C N/C Temperature Sensor Ignitor Shut Down Sensor Vacuum SwitchDeciding Where to Locate Your Pellet Appliance Vent Termination RequirementsFireplace Dimensions Removing Your NEW Stove from IT’S PalletMasonry Fireplace Insert INSTALLATION, Model FPI Clearance to CombustiblesFPI Pedestal Installation Assembling the Face Plate for the FPI ModelStandard 40 X 27 7/8 Freestanding INSTALLATION, Model FS Clearance to CombustiblesFreestanding Pedestal Installation AssemblyInstall Four Screws Here Horizontal Exhaust Through the Wall Through Wall Installation Inside Vertical Through the Roof Installation Outside Vertical Pipe Installation Mobile Home Installation Outside Fresh AIR ConnectionsTroubleshooting Stove will not startStove will not operate when hot Exhaust motor will not function normallyConvection blower will not function normally Igniter- the pellets will not lightAuger motor will not function normally Dial-a-fire has no effect on the fireStove will not shut down Stove keeps going outWiring Diagram Parts List Back GrillEF 4 Components ExplodedExploded Steel Components Warranty For the do-it-yourself IndividualTo the Dealer To the Distributor

EF-IV I specifications

The Enviro EF-IV I is an innovative next-generation environmental control unit designed to meet the diverse needs of modern aviation. With a strong focus on efficiency, reliability, and sustainability, the EF-IV I has garnered attention for its cutting-edge features and advanced technologies that elevate cabin comfort while reducing the ecological footprint.

One of the most notable features of the Enviro EF-IV I is its hybrid cooling technology. By integrating both conventional and thermal energy systems, the unit can operate with higher efficiency across various conditions. This technology allows for significant energy savings while maintaining optimal temperature control in the cabin, making it an ideal choice for eco-conscious airlines looking to minimize operational costs.

The EF-IV I boasts a sophisticated air filtration system that enhances cabin air quality. Utilizing advanced HEPA filters and multi-layer filtration processes, this unit captures airborne particles and contaminants, ensuring that passengers breathe clean and fresh air during their flights. Its intelligent monitoring system continuously assesses air quality parameters and adjusts filtration performance in real-time, providing a proactive approach to maintaining a healthy cabin environment.

In terms of user interface, the EF-IV I is equipped with an intuitive digital control panel that allows crew members to easily monitor and adjust settings. This interface features an interactive display providing valuable data on system performance, energy consumption, and maintenance schedules, empowering operators with real-time insights that contribute to seamless operations.

The compact design of the EF-IV I facilitates easier installation and integration into existing aircraft systems, making it a flexible choice for both new aircraft and retrofitting older models. Its lightweight materials and streamlined construction not only minimize weight and improve fuel efficiency but also enhance overall durability and reduce maintenance requirements.

Finally, the Enviro EF-IV I is built with sustainability in mind. Its materials and manufacturing processes are compliant with international environmental standards, ensuring that the unit adheres to stringent regulations and contributes positively to the overall environmental impact of aviation.

With its advanced features, sustainability focus, and commitment to enhancing passenger experience, the Enviro EF-IV I represents a significant step forward in environmental control technology for the aviation industry. It is a testament to the ongoing innovation and dedication to creating a more sustainable future in air travel.