Enviro 50-1221 technical manual Through vent hole, Exterior Blower Kit

Page 15

Installation

EXTERIOR MOUNTED EXHAUST BLOWER (20-070):

The Mini can be equipped with an externally mounted exhaust blower. This optional kit includes all components necessary to install the exhaust blower on any vertical wall surface.

Choose a location for your stove that meets the requirements stated in your manual and allows installation with the least amount of interference with house framing, plumbing, wiring, etc.

Included in the Exterior Mounted Exhaust Blower Kit are: 1 - Exhaust blower housing box.

1 - Blower cover plate.

1 - Hardware bag

Figure 19: Exterior Blower Kit.

 

1.

Remove the left hand cabinet side by removing the two

 

 

(2) screws down the front. Loosen the three screws on the

 

 

back of the cabinet side and remove panel.

 

2.

Loosen the six (6) screws that hold the back grill in place.

 

 

Lift the back grill off the screws.

 

3.

Disconnect the Exhaust blower wires from the wire

 

 

harness. Remove the exhaust blower motor from the

 

 

housing; six (6) screws. Cover hole in housing with cover

 

 

plate provided (see Figure 20).

Figure 20: Exterior Blower Kit.

4. Remove the cover from the exhaust blower housing box.

 

5.

Install the exhaust blower housing box into the pipe placed

 

 

through the wall thimble, seal with high temperature

 

 

silicone. Fasten the box to the wall with (4) four screws,

 

 

seal edges of box to wall with clear silicone.

 

6.

Drill a hole through the wall thimble plate for the electrical

 

 

wires. Pass the armored cable through the wall thimble.

 

 

Use the strain relief provided. Do not pass cable

 

 

through vent hole.

 

7. Install the Exhaust Blower motor into the external exhaust

 

 

blower housing box. Make the electrical connections to the

 

 

wire harness and exhaust blower.

 

8.

Replace the cover on the Exhaust Box and the back grill of

 

 

the stove and ensure the screws are tightened down.

Figure 21: Exterior Blower Kit cut-through.

9.

Install vertical pipe as instructed in appropriate section.

 

 

15

Image 15
Contents Mini Table of Contents Introduction Introduction Screws to take out to remove stove from Pallet InstallationDimensions of Mini 91.5 cm Crawlspace, narrow Walkway Closely Fresh AIR Intake 75mm Wall thimble Manufactured by pellet vent manufacturer Allows installation with the least amount Is the recommended installation set up Place a non-combustible hearth pad where Refer to Figures 17 Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit Sheathing To install the Optional slider damper rod, remove the left Special Notes Kit Components Installing the PanelsInstalling Hopper Lid Installing Hopper LidTroubleshooting Stove will not operate when hotStove will not start 200 F 93 C high limit temperature sensor has tripped Exhaust motor will not function normallyLight # 2 on Heat output bar flashing Stove keeps going out Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not light5V DC Wiring DiagramReference Description Part Number Parts ListParts List Parts Diagram Components Parts Diagram Steel For the do-it-yourself Individual WarrantyName of Owner Address Installation Data Sheet