Installation

CLEARANCES TO COMBUSTIBLES:

IMPORTANT: Attach the Mini’s Hearth Pad when installing the unit on a combustible floor. The supplied hearth pad meet all the requirement of a proper hearth pad. If you do not use the supplied hearth pad a hearth pad must be used when on combustible material.

Back Wall

3"

 

(7.5cm)

 

4" (10cm)

8"

 

(20cm)

 

Side Wall

 

Figure 4: Mini Clearance to Combustibles.

If the Mini is installed on carpet the use of a solid material must be used under leveling legs.

These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine cleaning and maintenance.

Side wall to unit

8 inches

(20 cm)

Back wall to unit

4 inches

(10 cm)

Corner to unit

3 inches

(7.5 cm)

ALCOVE CLEARANCES:

This unit may be installed in an alcove. Maintain these clearances to combustibles.

Minimum Alcove width

36 inches

(91.5 cm)

Minimum Alcove height

48 inches

(122 cm)

Maximum Alcove depth

30 inches

(76 cm)

Install vent at clearances specified by the vent manufacturer.

36"

(91.5cm)

48"

(122cm)

30"

(76cm)

Figure 5: Mini Minimum Alcove Size.

7

Image 7
Contents Mini Table of Contents Introduction Introduction Screws to take out to remove stove from Pallet InstallationDimensions of Mini 91.5 cm Crawlspace, narrow Walkway Closely Fresh AIR Intake 75mm Wall thimble Manufactured by pellet vent manufacturer Allows installation with the least amount Is the recommended installation set up Place a non-combustible hearth pad where Refer to Figures 17 Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit Sheathing To install the Optional slider damper rod, remove the left Special Notes Kit Components Installing the PanelsInstalling Hopper Lid Installing Hopper LidStove will not operate when hot TroubleshootingStove will not start Exhaust motor will not function normally 200 F 93 C high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Stove keeps going out Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not light5V DC Wiring DiagramReference Description Part Number Parts ListParts List Parts Diagram Components Parts Diagram Steel For the do-it-yourself Individual WarrantyName of Owner Address Installation Data Sheet