| Installation | ||
INSIDE VERTICAL INSTALLATIONS: |
|
| |
���� ��� ������� ��� �� | 1. | Choose a stove location that is ideal. See the | |
| section “DECIDING WHERE TO LOCATE YOUR PELLET | ||
�� ����� ��� ����� ��� |
| ||
� �� | APPLIANCE.” | ||
| |||
���� �� ��� ������ ������ | ���� ��� | ||
|
| ||
���� �������� | 2. | Place a | |
| necessary. | ||
���� ������ |
| ||
3. | Place the unit on the hearth pad (if installed | ||
���� ���� ���� | |||
������� ������ |
| on a combustible surface) and space the | |
������� ����� |
| unit in a manner so when the pellet vent is | |
|
| installed vertically, it will be 3” (7.5 cm) away | |
|
| from a combustible wall. | |
�������� ���� ���� | 4. | Install the tee with clean out. | |
5. | Install the pellet vent upward from there. | ||
| |||
|
| When you reach the ceiling, make sure | |
|
| that the vent goes through the ceiling fire | |
|
| stop. Maintain a 3” (7.5 cm) distance to | |
����� ��� ��� ���� |
| combustibles and keep attic insulation away | |
���� ������� |
| from the vent pipe. Maintain an effective | |
|
| ||
|
| vapor barrier. | |
����� ��� ���� �������� ���� | 6. | Finally, extend the pellet vent to go through | |
�������� � ������ ���� ��� |
| the roof flashing. | |
���������� �� ������������� |
| ||
|
| ||
| 7. | Ensure that the rain cap is approximately 24” | |
Figure 15: Inside Vertical Installation. | (600 mm) above the roof. | ||
| |||
OUTSIDE VERTICAL INSTALLATIONS: |
|
|
To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “INSIDE VERTICAL
INSTALLATIONS - FREESTANDING” section and then finish it
by performing the following (refer to Figure 16).
Rain cap
Flashing
24"
(61 cm)
1.Install a tee with clean out on the outside of the house.
2.Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent straight and secure.
3.Install ceiling thimble and secure the flashing as you go through the roof.
4.Ensure that the rain cap is approximately 24” (600 mm) above the roof.
4" |
(10 cm) |
3" (7.5 cm) Clearance
Support bracket
Tee with cleanout
Type "PL"
vent
Figure 16: Outside Vertical Installation.
13