Enviro 1700 Fireplace Insert, C-10240, 1700 Freestanding, 1200 Fireplace Insert, 50-1040 Outside AIR

Page 27

Installation

These connectors must be installed in accordance with the manufacturer’s instructions. Use only specified components. The chimney and pipe must extend at least 10 feet (2.4 m) above the stove and 3 feet (0.9 m) above the highest point of the roof. Install a rain cap with spark arrestor at the top that will not impede the smoke exhaust. The chimney must be supported at the ceiling or roof so that its weight will not sit on the stove. Seal with silicone to maintain vapor barrier at the chimney and outside air penetrations.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.

OUTSIDE AIR :

Connection from the stoves air intake to the outside is mandatory, (MOBILE HOMES ONLY) either through a hole in the wall not higher than the stoves bottom or through a hole in the floor beneath the pedestal, using the fresh air adaptor provided. If the air intake is through the floor, the hole in the pedestal back must be closed with the sheet metal cover provided. Avoid cutting any floor joists, wall studs, electrical wiring or plumbing. Seal around the outside air pipe with insulation to prevent drafts. Also install a 1⁄4” mesh rodent or pest screen in the end of fresh-air pipe. Fresh-air connection must be of a non-combustible material, example: 4” (10.16 cm) flexible aluminum single wall pipe.

Fresh air could also be supplied from a vented crawlspace.

 

Spark arrestor cap

At least

Roof flashing

3 feet (914 mm)

Roof

 

Insulated

Radiation Shield

chimney

 

Ceiling

Ceiling support

 

 

Double wall pipe

 

Woodstove

Optional

 

fan

 

 

Pedestal

 

Hearthpad

Outside air connection

Floor

through wall or floor

Bolt stove to floor

Figure 28: Freestanding installation into mobile home.

The pedestal must be firmly bolted to the floor using two (2) 1⁄4” bolts. Be sure to replace any insulation or panels removed when fastening the bottom nuts.

If room air starvation occurs because the air intake is blocked with ice, leaves etc. or because the stove door was left open, or due to a strong exhaust fan operating, dangerous fumes could be sucked into the room.

IN SOME AREAS IT MAY BE REQUIRED TO ELECTRICALLY GROUND THE STOVE TO THE STEEL CHASSIS OF THE MOBILE HOME.

When this unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a grounding rod.

Manufactured (Mobile) home installation must be in accordance with the Manufactured Home Construction and Safety Standard, UL 307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A.

WARNING: DO NOT INSTALL IN A MOBILE HOME SLEEPING ROOM.

27

Image 27
Contents Wood Stove Table of Contents Safety Precautions First Start Operating InstructionsCreosote ITS Formation and Removal Helpful Hints Worth Repeating What type of wood is best to use as firewood? What can cause a poor draft? 1200 Air Flow Path Specifications Capacity Feet3 0.0708 meter3 Approximate heating area † From front of unit to edge of floor protection Maintain These Minimum Clearances to Unshielded Combustibles 1700 Freestanding Clearance to Combustibles 1200 Insert Dimensions 1200 Freestanding Flat Top Dimensions 1700 Freestanding Flat Top Dimensions 1200 Freestanding with Fan Kit Dimensions Bolts to remove InstallationInstalling Heat Shield Recommended Height for Flue Pipe Chimney Through Wall Method a Roof Clearances Shield if required Installation into a masonry chimney Venting Outside AIR Insert Installation into existing fireplace With hearth Attaching removable flue Total Bricks Model 1700 Brick Placement Do not USE Door if Glass is Broken Installation of Ceramic Baffle Back View of Freestanding Unit with Fan Kit Removal of right pod This will keep the trim tight Parts List Parts List Parts Diagram Parts Diagram Pedestals & Legs Parts Diagram Fireplace Insert Limited Five 5 Year Warranty Limited One 1 Year Warranty WarrantyExclusions and Limitations Warranty Installation Data Sheet