Enviro EF THERMO 28 technical manual Termination Cap Gas Meter Air Supply Inlet Restriction Zone

Page 11

 

 

 

Installation

 

 

 

 

 

 

K

G

 

 

 

 

 

 

 

 

 

 

 

E

 

D

F

 

Opens

B

C

G

 

 

 

G

 

 

Opens

 

 

 

 

 

 

 

 

 

B

 

A

I

Opens

L

 

 

 

 

 

 

 

 

Termination Cap

G Gas Meter

H

 

 

 

Air Supply Inlet

Restriction Zone

 

 

 

 

 

(Termination not allowed)

 

Figure 13

1.Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow walkway, closely fenced area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, covered breezeway, etc.

2.Vent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required.

3.Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be installed outside when the appliance is vented directly through a wall, to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure. This will keep exhaust from causing a nuisance or hazard from exposing people or shrubs to high temperatures. In any case, the safest and preferred venting method is to extend the vent through the roof vertically.

4.Distance the from bottom of the termination and grade is 12” (30 cm) minimum. This is conditional upon the plants and nature of grade surface. The exhaust gases are hot enough to ignite grass, plants and shrubs located in the vicinity of termination. The grade surface must not be lawn.

5.If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since these factors are beyond the control of Sherwood Industries Ltd, we grant no guarantee against such incidents.

NOTE: Venting terminals shall not be recessed into walls or siding.

11

Image 11
Contents Technical Manual Table of Contents Introduction Introduction Specifications Unit Dimensions Air Bleeder Valve shown in Figure Water Temperature Limit Switch Located behind rightAsh drawer Cover Installation Installation of Expansion Tank Termination Cap Gas Meter Air Supply Inlet Restriction Zone Back wall to unit Inch Supply Horizontal Through Wall Installation Through Wall Installation Inside Vertical Installation Outside Vertical Installation Homes as well as in Air Tight homes Thermostat InstalledStove will not start TroubleshootingStove will not operate when hot Ignitor- the pellets will not light Control settings Heat Level have no effect on the fireExhaust motor will not function normally Convection blower will not function normallySetting. Has lights 1 Water Temperature Dial Read in degrees CelsiusIs solid, setting can be altered Heat Output Indicator Shows the present heat outputWiring Diagram Reference Part Description Part Number Parts ListParts Diagram Components Parts Diagram Body For the do-it-yourself Individual WarrantyName of Owner Address Installation Data Sheet

EF THERMO 28 specifications

The Enviro EF THERMO 28 is a cutting-edge multifuel stove that exemplifies efficient heating and contemporary design, making it an attractive option for homeowners seeking both functionality and aesthetics. This stove is engineered to optimize performance while reducing environmental impact, aligning with today’s energy-conscious lifestyles.

One of the standout features of the EF THERMO 28 is its impressive efficiency rating. It boasts an efficiency level of over 80%, ensuring that a significant portion of the fuel burned is converted into usable heat. This high efficiency minimizes fuel consumption, making it not only cost-effective but also environmentally friendly by decreasing emissions.

The stove is designed to burn a wide range of fuels, including wood, pellets, and even coal, providing users with flexibility depending on their heating needs and fuel availability. The advanced combustion system employed in the EF THERMO 28 utilizes secondary air injection, which promotes a cleaner burn and enhances overall heating performance. This technology not only contributes to lower emissions but also ensures that the stove operates effectively even in varying conditions.

Another notable characteristic of the EF THERMO 28 is its robust construction. Built from high-quality steel and equipped with a ceramic glass door, the stove is designed to withstand high temperatures while maintaining safety and durability. The design also features a large viewing window, allowing for an inviting aesthetic appeal as flames dance within the firebox.

The stove’s intuitive control system is user-friendly, featuring an adjustable air control that allows users to fine-tune the burn rate for optimal heat output. This enables more precise heating management, enhancing comfort in the home while also conserving fuel. Additionally, its compact size makes it suitable for various spaces, whether it be a rustic cabin or a modern home.

Overall, the Enviro EF THERMO 28 represents a blend of innovation, efficiency, and style. With its multifuel capabilities, high efficiency, advanced combustion technologies, and user-friendly features, this stove is an ideal choice for those looking to enhance their heating experience while adhering to eco-friendly practices. Whether for primary heating or supplementary warmth, the EF THERMO 28 provides an effective solution that caters to diverse preferences and needs in home heating.