Installation
CLEARANCES TO COMBUSTIBLES:
C |
B |
A |
Floor Protection |
Figure 14
This unit can be installed on a combustible floor due to the built in pedestal hearth pad (for example linoleum, hardwood flooring). If combustible flooring is underneath the unit 6 inches (153 mm) on either side and to the front must be protected by
NOTE: These dimensions are minimum clearances but it is recommended that you ensure sufficient room (20” [508 mm]) on either side) for servicing, routine cleaning and maintenance.
Do not block any of the air intake grills.
Maintain these clearances to combustibles.
A) Side wall to unit | 6 inches | (153 mm) | |
B) Back wall to unit | 1 inch | ( | 25 mm) |
C) Adjacent wall to corner of unit | 1 inch | ( | 25 mm) |
- Mantle (Hearth Mount) | 8 inches | (203 mm) |
ALCOVE CLEARANCES:
This unit may be installed in an alcove. Maintain clearances to combustibles.
Minimum Alcove width | 36 inches | ( | 914 mm) |
Minimum alcove height | 48 inches | (1220 mm) | |
Maximum alcove depth | 30 inches | ( | 762 mm) |
Install vent at clearances specified by the vent manufacturer.
36" (90cm) |
48" |
(120cm) |
Figure 15