Enviro EG40-071 owner manual Turn the unit off and remove the log set

Page 10

Initial Installation

REPLACING THE BLOWER:

 

1.

Turn the unit off and remove the log set.

2.

Remove the brick liner.

3.

Remove the burner tray assembly by removing the

 

screw on either side of the tray, between the front and

 

rear burners. Lift the tray out.

4.

Remove the four (4) 5/16” bolts that hold the blower

 

mounting plate to the back firewall. Use a light

 

lubricating oil on screws before removal.

5.

Carefully pull the blower assembly into the firebox

 

(see Figure 8) disconnect the blower leads from the

 

harness and remove blower.

6. To re-install, check mounting plate gasket if damaged

 

replace with new one and reverse steps 1 through 4.

 

Refer to “Secondary Installation - Installation of Panel

 

Set” and “Secondary Installation - Installation of Log

 

Set and Embers”.

Figure 8: Blower (Fan) Removal.

 

ADJUSTING THE VENTURIES:

There is a separate venturies for each burner, see Figure 9.

Remove one screw from the cover plate located below the ash shelf and loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.

With along screwdriver rotate spring clips to open or close the venturies to the desired setting.

The venturies allows the amount of air coming into the fireplace to be adjusted in order to accommodate different climates and venting arrangements. Start the pilot and then the burner. Make sure the pilot flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly fifteen9minutes and then examine the flames, compare the flames to Figure 16.

Rear log holder

 

Front log holder

Ember tray &

Rear burner

front burner

 

Door

Venturies

Screwdrive

 

 

Gold bar

Air shutter cover plate

Figure 9: Venturi Adjustment.

The ideal flame will be blue at the base and light orange above. The flames should be of medium height. If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, the fireplace is getting too much air. Therefore, the venturies should be closed slightly until the correct flames are achieved. Flames that are very orange, with tall, dark, stringy tips, are not getting enough air. Open the venturi until the flames clean up. If the venturi is opened, or closed all the way, and the correct flames cannot be attained, turn off the gas and contact the dealer.

Warning: Incorrect venturi adjustment may lead to improper combustion, which is a safety hazard. Contact the dealer if there is any concern about the venturi adjustment.

10

Image 10 Contents
EG40 BV For Your Safety Safety PrecautionsGeneral Table of Contents Codes And Approvals Vented GAS Fireplace Heater EG40 BV NG/LPGSpecifications EG40 Exterior Dimensions Initial Installation Qualified Installers onlyHeight of Vertical Termination Straight vertical installation Wiring of a Thermostat Turn the unit off and remove the log set 50% turn down HI-LOW Regulator GAS Line Connection To Test Valve PressuresSecondary Installation Log PlacementLog Placement with Embers Operating Instructions What to do if YOU Smell GASCleaning Plated Surfaces Routine Maintenance and ServiceCleaning the Inside of the Firebox Opening the DoorTrouble Shooting Problem Possible Cause SolutionParts List Reference Part Description Part Number Parts Diagram Chassis Diagram Gas Tray & Door PartsWarranty To the DistributorInstallation Data Sheet