Enviro C-11150 technical manual Cabinet side and locate the slider damper plate. Install

Page 19

Installation

THERMOSTAT INSTALLATION:

1.Install the wall thermostat in a location that is not to close too the unit but will effectively heat the desired area.

2.Install a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat.

If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the control board Heat Indicator. If the heating load is not great enough when the stove is on low, the high limit switch will turn the stove off and the switch will have to be manually reset. To reset the high limit switch, remove the right cabinet side. The switch is found behind the control panel. Avoid setting off the high limit switch.

Figure 25: Thermostat wire placement.

OPTIONAL SLIDER/DAMPER INSTALLATION:

If you wish to adjust the slider damper externally (NOT REQUIRED), please follow the instructions below.

 

 

Slider damper

 

 

rod and knob

 

 

7/16" Nut

 

Slider damper plate

7/16" Clinching Nut

 

Figure 26: Slider/Damper Assembly.

 

1. To install the OPTIONAL slider damper rod, remove the left

 

cabinet side and locate the slider damper plate. Install the

Slider/Damper

7/16” inch nut onto the slider damper rod, thread all the

way to the end of the threads on rod.

Knob

 

2. Slide rod through the hole in the slider damper plate and

 

install the 7/16” clinching nut onto the rod and tighten

 

completely onto the slider damper plate.

 

3. Re-install the cabinet side. Install the black knob on the

 

end of the rod. Check slider damper for smooth operation.

Figure 27: Slider/Damper Knob.

 

 

19

Image 19
Contents Mini Table of Contents USE of Cordwood is Prohibited by LAW IntroductionIntroduction Introduction Screws to take out to remove stove from Pallet InstallationDimensions of Mini 91.5 cm Letter Minimum Clearance Description Fresh AIR Intake 75mm Wall thimble Manufactured by pellet vent manufacturer Allows installation with the least amount Is the recommended installation set up Place a non-combustible hearth pad where Refer to Figures 17 Exterior Blower Kit Through Wall Installation with Exterior Blower Kit Sheathing Cabinet side and locate the slider damper plate. Install Special Notes Kit Components Installing the PanelsInstalling Hopper Lid Installing Hopper LidStove will not operate when hot TroubleshootingStove will not start Exhaust motor will not function normally 200 F 93 C high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Stove keeps going out Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not lightWiring Diagram Reference Description Part Number Parts ListParts List Parts Diagram Components SDiagramPartsteel To the Dealer WarrantyTo the Distributor Exclusions and Limitations Warranty Name of Owner Address Installation Data Sheet

C-11150 specifications

Enviro C-11150 is a state-of-the-art equipment designed to address the increasing demand for efficient environmental management solutions in industrial applications. This machine stands out in the market due to its high-performance capabilities, which help businesses optimize their operations while adhering to strict environmental regulations.

One of the main features of the Enviro C-11150 is its advanced filtration system. This technology utilizes multiple stages of filtration, ensuring that even the smallest particulate matter is effectively eliminated from water, air, and other waste streams. This not only enhances the overall quality of the output but also guarantees compliance with environmental standards, minimizing the risk of penalties and fines for businesses.

The Enviro C-11150 is equipped with an innovative control system that allows for seamless monitoring and management of various environmental parameters. Users can easily access real-time data and analytics through a user-friendly interface, enabling them to make informed decisions. Additionally, the system is designed for remote monitoring, allowing operators to keep track of their processes from anywhere, enhancing operational efficiency.

Another critical characteristic of the Enviro C-11150 is its energy-efficient design. By incorporating cutting-edge technologies, the machine reduces energy consumption significantly, leading to lower operational costs for users. This is particularly important for industries looking to minimize their carbon footprint and promote sustainability in their practices.

The Enviro C-11150 also boasts a compact design, making it suitable for a variety of installation environments. Despite its small footprint, it delivers robust performance, effectively accommodating the needs of different sectors, from manufacturing to waste management.

Moreover, the machine is constructed with high-quality materials that ensure durability and longevity. This minimizes maintenance requirements and downtime, which is advantageous for businesses aiming to maintain uninterrupted operations.

In conclusion, the Enviro C-11150 is a revolutionary solution in the field of environmental management. Its advanced filtration system, innovative control technologies, energy efficiency, compact design, and durable construction collectively make it an excellent choice for industries seeking to enhance their environmental practices while maintaining high operational standards.