Avalon Stoves Rainier owner manual Chimney Requirements, Drafting

Page 10

10 Stove Installation (for qualified installers only)

Chimney Requirements

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE .

Chimney connector must be a minimum 24 MSG black or 26 MSG blued steel (6" diameter). Chimney must be used from the first floor or wall penetration to the chimney cap.

Use 6" diameter type UL 103 HT chimney from one manufacturer (do not mix brands) or code approved masonry chimney with a flue liner.

Chimney connector and chimney must be fastened to the stove and each adjoining section.

Follow the chimney manufacturer's clearances and requirements.

Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when passing through a ceiling or thimble when passing through a combustible wall.

No more than 180o of elbows (two 90o elbows, or two 45o & one 90o elbow, etc.).

NOTE: Additional elbows may be allowed if draft is sufficient. Whenever elbows are used the draft is adversely affected. Additional chimney height may be required to boost draft.

 

 

Chimney Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(See the section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Chimney Termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

}

 

 

Minimum System 15'

 

 

 

 

Requirements" for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum System 33'

 

 

 

 

more details)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof Penetration Equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Built

 

 

 

 

 

 

 

 

 

 

 

 

(Roof Radiation Shield,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flashing, Storm Collar)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling Penetration

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Air Space to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Equipment (Attic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustibles (See

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Radiation Shield with

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney Manufacturer's

 

 

 

Chimney Support)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructions - usually 2")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard residential installations with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reduced

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reduced clearance connector may use the

 

 

 

 

 

Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clearance determined by the manufacturer

 

 

 

 

 

Chimney

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the connector for the connector to wall

 

 

 

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clearance or the clearance listed in this

 

 

 

 

 

Sections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mobile home installations must use the

 

 

 

 

 

Floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the reduced clearance connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clearances listed in this manual under

 

 

 

 

 

Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Additional Requirements for Mobile Home

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installations”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(as outlined in this manual)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drafting

This appliance relies upon natural draft to operate. External forces, such as wind,

 

Performance barometric pressure, topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries can not be responsible for external forces leading to less than optimal performance.

• Standard residential installations may use single-wall connector (Mobile-Homes may n o t)

Standard residential installations with reduced clearance connector may use the clearance determined by the manufacturer of the connector for the connector to wall clearance or the clearance listed in this manual. Offsets must be used to maintain the stove to wall clearance. Mobile homes must use the clearances listed in this manual under "Additional Requirements for Mobile Home

Installations".

Travis Industries

100-01140

4 020628

Image 10
Contents Rainier T r o d u c t i o n Important Information Mail your Warranty Card Today, and Save Your Bill of Sale2Introduction Travis Industries 100-01140 050124Table of Contents Safety Precautions AshesMobile Home6Features & Specifications Stove Installation Considerations Planning The InstallationPreparation for Installation Installation Type ConsiderationsFloor Protection Requirements Stove Placement Requirements ClearancesChimney Requirements DraftingSlanted Roofs Chimney Termination RequirementsOutside Air Requirements FlatSee Illustration below Alcove Installation RequirementsRainier Minimum Clearance Combustible Non-CombustibleMobile Home Requirements With Reduced Clearance ConnectorMinimum Clearance Rainier See Illustration below Chimney Cap See the section Chimney T e r i o r C t o r y I l t I m n e y T EInterior or Exterior Masonry Chimney 28 to 144 not approved for zero Insert Installation ConsiderationsSurround Panels Clearance fireplacesInsert Size Requirements see Illustration below Insert Placement RequirementsHearth Requirements Zero-Clearance Metal Fireplace Requirements Leveling Bolt InstallationMasonry Fireplace Requirements Drafting PerformanceBlock-Off Plate Installation Block-Off Plate TemplateInsert with Positive Connection Insert with Before Your First Fire Safety NoticeOperating Your Appliance Opening the DoorStarting a Fire Approximate Air Control Settings Adjusting the Burn RateAsh Removal Overnight Burn Optional Blower OperationRe-Loading the Stove Normal Operating SoundsHints for Burning Selecting WoodTroubleshooting Maintaining Your Appliance Daily Maintenance while stove is in useClean the Glass if necessary Remove Ash if necessaryDoor and Glass Inspection Monthly Maintenance while appliance is in useCreosote Formation and Need for Removal Touch Up Paint Yearly MaintenanceCleaning the Air Duct and Blower if applicable Firebrick and Baffle InspectionReplacing the Door Gasket Door PartsReplacing the Glass Replacing the Door HandleFirebox Parts Floor and Side Firebrick Removal & ReplacementTravis Industries 100-01140 060417 Air Tube Removal & Replacement Baffle Removal & ReplacementYears 3 Through 5 Coverage Parts & Labor Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyFreestanding Installation Listing LabelPedestal Optional EquipmentTravis Industries 100 080103 Outside Air Installation for wood stoves only Top ViewRear Blower Installation Part number Install the wire clip following the directions belowOutside Air Boot Installation Part number Travis Industries 100-01140 051104 Required for face seal installations onlySurround Panels see s below Z e Size on Insert w trimTo Switch the Power Cord to the Left Side Front BlowerOptional Equipment 44Index

Rainier specifications

Avalon Stoves has long been synonymous with quality and innovation in the fireplace and heating industry. Among its distinguished lineup is the Avalon Rainier, a stove that embodies both modern aesthetics and cutting-edge heating technology. Designed for those who appreciate the warmth of a fire while also seeking efficient heating solutions, the Rainier stands as a testament to Avalon’s commitment to excellence.

One of the standout features of the Avalon Rainier is its impressive heating capacity. With the ability to heat spaces up to 2,000 square feet, this stove is perfect for larger homes or open-concept living areas. The Rainier boasts a powerful EPA-certified firebox, which enhances its efficiency and reduces emissions, ensuring that you not only enjoy the ambiance of a fire but also adhere to modern environmental standards.

The stove's advanced combustion technology is another remarkable characteristic. The Rainier employs a secondary combustion system, allowing for a cleaner burn and maximized heat output. This system significantly reduces the amount of smoke produced, providing a more pleasant experience while increasing the lifespan of the stove. The result is a cleaner environment and extended fuel efficiency.

In terms of design, the Avalon Rainier does not disappoint. It features a contemporary aesthetic that can seamlessly integrate into any home decor. With various finishes and optional tile surrounds, personalization is easy, allowing homeowners to dial up their unique style. The large viewing window enhances the visual appeal of the fire, inviting the warm glow into any room.

User-friendly functionalities set the Rainier apart from its competitors. The stove includes an intuitive air control system that allows for precise adjustments of the heat and burn rate. Additionally, the optional blower system enhances air distribution, ensuring that even the far corners of your home receive optimal warmth.

Durability is paramount in the construction of the Avalon Rainier. Made from high-quality materials, including heavy-duty steel and cast iron, the stove is built to withstand the rigors of daily use while maintaining its elegant look.

In summary, the Avalon Stoves Rainier offers an impressive combination of heating efficiency, desirable aesthetics, and user-friendly features. Whether you are looking to reduce your heating costs or simply enjoy the cozy atmosphere of a wood-burning fire, the Rainier is an excellent choice that exceeds expectations. Its commitment to both performance and design makes it a standout option for any homeowner.