42 | Optional Equipment |
Front Blower (part # 99000137)
TO SWITCH THE POWER CORD TO THE LEFT SIDE:
Follow the directions below to switch the power cord. Make sure the power cord, wires, or molex assembly do not protrude into the opening of the blower.
The wires tuck in here, directly behind the blower cage.
Remove the strain relief by
squeezing it from the top and bottom
with a pair of
Disconnect the molex plug inside the blower assembly. Remove the power cord by pulling it out of the hole exposed by removing the strain relief.
Left Side of
Blower
Assembly
Remove the button plug from the
left side and insert it into the hole
on the right side.
INSTALLATION INSTRUCTIONS
1.The Rainier (945/990) and Olympic (1190), require removal of the button plug below the blower knob and installation of the air control rod extention (see illustration below).
2.Install the snap disk (see the illustration below. The round disc must be facing upwards and come in contact with the bottom of the firebox for the blower to operate correctly.
Ashlip of Appliance
Bend these legs on the snap disk if it does not fit tightly
Wedge the snap disk in back of the stiffener on the left side
The air control extender allows the air control rod to pass through the blower assembly on the Rainier (945/990) and Olympic (1190).
Button Plug for Air Control Rod
Wood Air Control Handle
(For the Rainier (945/990) and Olympic (1190)
3.Make sure the wires leading to the snap disk are routed above the left side blower outlet (to prevent damage to the wires during installation). Install the blower following the directions below.
ake sure the wires run over he top of the blower housing nd are not damaged when the lower is installed.
his clip aligns the blower nside the convection channel.
Insert the baseplate of the appliance into this gap.
This clip slips over the edge of the appliance unibody and locks the blower in place.
Baseplate of Appliance
(Below Ashlip)
Front of
Appliance
Travis Industries | 4 020628 |