Avalon Stoves Rainier owner manual Chimney Cap See the section Chimney

Page 14

14 Stove Installation (for qualified installers only)

S t a n d a r d Ceiling with

aFactory Built Chimney

Cathedral Ceiling with

aFactory Built Chimney

Chimney Cap

 

 

 

(See the section "Chimney

 

 

 

Termination Requirements"

 

 

Follow the chimney

for more

 

}

 

 

manufacturer's instructions

 

 

and clearances for roof

 

 

penetrations. A storm collar

 

 

and flashing are required

 

 

(some require a radiation

Chimney Sections

 

shield).

 

 

Insulation

}

 

Follow the chimney

 

 

manufacturer's instructions

 

Minimum Air Space to

and clearances for floor

 

 

Combustibles (See

penetrations. A ceiling

 

Chimney Manufacturer's

support is required, an attic

 

 

Instructions - usually 2")

insulation shield is required

 

where insulation is present.

 

 

 

 

 

 

Minimum 15'

Chimney Connector Sections

 

Maximum 33'

 

 

Floor Protection

 

 

 

 

 

 

 

Stove Clearances

(See the section "Floor

 

 

 

 

 

 

 

Protection Requirements"

 

 

 

 

 

 

 

(See the section "Stove

for more details)

 

 

 

 

 

 

 

Placement Requirements"

 

 

 

 

 

 

 

 

 

 

for more details)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(See the section "Chimney

 

 

 

 

 

 

 

 

Termination Requirements"

 

 

 

 

}

 

for more details)

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow the chimney

Chimney Sections

 

 

 

 

 

 

 

manufacturer's instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and clearances for roof

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

penetrations. A storm

Minimum Air Space to

 

 

collar, flashing, and

Combustibles (See Chimney

 

 

 

 

 

 

cathedral-style chimney

Manufacturer's Instructions -

 

 

 

 

 

 

support are required

usually 2")

 

 

 

 

 

 

(some require a radiation

 

 

 

 

 

 

 

 

 

 

 

shield).

 

 

 

 

 

 

 

 

 

 

 

 

Chimney

Minimum 15'

Maximum 33'

Connector

 

Sections

 

Floor Protection

Stove Clearances

(See the section "Floor

(See the section "Stove

Protection Requirements"

Placement Requirements"

for more details)

for more details)

 

Travis Industries

100-01140

4 020628

Image 14
Contents Rainier T r o d u c t i o n Important Information Mail your Warranty Card Today, and Save Your Bill of Sale2Introduction Travis Industries 100-01140 050124Table of Contents Safety Precautions AshesMobile Home6Features & Specifications Stove Installation Considerations Planning The InstallationPreparation for Installation Installation Type ConsiderationsFloor Protection Requirements Stove Placement Requirements ClearancesChimney Requirements DraftingSlanted Roofs Chimney Termination RequirementsOutside Air Requirements FlatSee Illustration below Alcove Installation RequirementsRainier Minimum Clearance Combustible Non-CombustibleMinimum Clearance Rainier See Illustration below With Reduced Clearance ConnectorMobile Home Requirements Chimney Cap See the section Chimney T e r i o r C t o r y I l t I m n e y T EInterior or Exterior Masonry Chimney 28 to 144 not approved for zero Insert Installation ConsiderationsSurround Panels Clearance fireplacesHearth Requirements Insert Placement RequirementsInsert Size Requirements see Illustration below Zero-Clearance Metal Fireplace Requirements Leveling Bolt InstallationMasonry Fireplace Requirements Drafting PerformanceBlock-Off Plate Installation Block-Off Plate TemplateInsert with Positive Connection Insert with Before Your First Fire Safety NoticeOperating Your Appliance Opening the DoorStarting a Fire Ash Removal Adjusting the Burn RateApproximate Air Control Settings Overnight Burn Optional Blower OperationRe-Loading the Stove Normal Operating SoundsHints for Burning Selecting WoodTroubleshooting Maintaining Your Appliance Daily Maintenance while stove is in useClean the Glass if necessary Remove Ash if necessaryCreosote Formation and Need for Removal Monthly Maintenance while appliance is in useDoor and Glass Inspection Touch Up Paint Yearly MaintenanceCleaning the Air Duct and Blower if applicable Firebrick and Baffle InspectionReplacing the Door Gasket Door PartsReplacing the Glass Replacing the Door HandleTravis Industries 100-01140 060417 Floor and Side Firebrick Removal & ReplacementFirebox Parts Air Tube Removal & Replacement Baffle Removal & ReplacementYears 3 Through 5 Coverage Parts & Labor Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyFreestanding Installation Listing LabelTravis Industries 100 080103 Optional EquipmentPedestal Outside Air Installation for wood stoves only Top ViewRear Blower Installation Part number Install the wire clip following the directions belowOutside Air Boot Installation Part number Travis Industries 100-01140 051104 Required for face seal installations onlySurround Panels see s below Z e Size on Insert w trimTo Switch the Power Cord to the Left Side Front BlowerOptional Equipment 44Index

Rainier specifications

Avalon Stoves has long been synonymous with quality and innovation in the fireplace and heating industry. Among its distinguished lineup is the Avalon Rainier, a stove that embodies both modern aesthetics and cutting-edge heating technology. Designed for those who appreciate the warmth of a fire while also seeking efficient heating solutions, the Rainier stands as a testament to Avalon’s commitment to excellence.

One of the standout features of the Avalon Rainier is its impressive heating capacity. With the ability to heat spaces up to 2,000 square feet, this stove is perfect for larger homes or open-concept living areas. The Rainier boasts a powerful EPA-certified firebox, which enhances its efficiency and reduces emissions, ensuring that you not only enjoy the ambiance of a fire but also adhere to modern environmental standards.

The stove's advanced combustion technology is another remarkable characteristic. The Rainier employs a secondary combustion system, allowing for a cleaner burn and maximized heat output. This system significantly reduces the amount of smoke produced, providing a more pleasant experience while increasing the lifespan of the stove. The result is a cleaner environment and extended fuel efficiency.

In terms of design, the Avalon Rainier does not disappoint. It features a contemporary aesthetic that can seamlessly integrate into any home decor. With various finishes and optional tile surrounds, personalization is easy, allowing homeowners to dial up their unique style. The large viewing window enhances the visual appeal of the fire, inviting the warm glow into any room.

User-friendly functionalities set the Rainier apart from its competitors. The stove includes an intuitive air control system that allows for precise adjustments of the heat and burn rate. Additionally, the optional blower system enhances air distribution, ensuring that even the far corners of your home receive optimal warmth.

Durability is paramount in the construction of the Avalon Rainier. Made from high-quality materials, including heavy-duty steel and cast iron, the stove is built to withstand the rigors of daily use while maintaining its elegant look.

In summary, the Avalon Stoves Rainier offers an impressive combination of heating efficiency, desirable aesthetics, and user-friendly features. Whether you are looking to reduce your heating costs or simply enjoy the cozy atmosphere of a wood-burning fire, the Rainier is an excellent choice that exceeds expectations. Its commitment to both performance and design makes it a standout option for any homeowner.