Avalon Stoves Rainier owner manual Rear Blower Installation Part number

Page 39

Optional Equipment

39

Rear Blower Installation (Part number 99000138)

The rear blower improves heat transfer by pushing heated air through the convection channel. Operating instructions are described in the section "Blower Operation" on page 26.

1The stove should be in place with the legs installed prior to installing the rear blower.

2Follow the directions below to install the thermodisk.

These wires pass through the left side convection channel.

Air

Control

Rod

Thermodisk Assembly

 

Insert the thermodisk

Bend metal up or down

assembly 4" to 5" inside

here to create a snug fit

the convection channel.

3 Install the wire clip following the directions below.

Use a screwdriver to pry out the knock-out.

Slide the wire clip over the edge of the strip of metal between the two knock-outs.

Wire Clip

Snap Disk

Wires

Feed the two snap disk wires into the eye of the wire clip. Remove all slack from the wire, making sure not to dislodge the snap disk. Pinch the eye of the wire clip to secure the wires.

WARNING:

To prevent electrical shock, the wires must be secured so they do not contact the firebox above the convection channel.

4 Attach the blower following the directions below.

Attach the quick-connects

a leading from the snap disk to the quick-connects from the blower (orientation does not matter).

b

The blower attaches to the stove with the three

 

included screws. Use a 3/8” socket driver or wrench.

 

3/8" Nutdriver

NOTE:

Prior to attaching the blower, tuck all excess wire into the area inside the blower.

c

Plug the power cord into a 110 V. outlet after installing the

 

blower.

Travis Industries

100-01140

4 020628

Image 39 Contents
Rainier Travis Industries 100-01140 050124 Mail your Warranty Card Today, and Save Your Bill of Sale2Introduction T r o d u c t i o n Important InformationTable of Contents Ashes Safety PrecautionsHome Mobile6Features & Specifications Installation Type Considerations Planning The InstallationPreparation for Installation Stove Installation ConsiderationsFloor Protection Requirements Clearances Stove Placement RequirementsDrafting Chimney RequirementsFlat Chimney Termination RequirementsOutside Air Requirements Slanted RoofsCombustible Non-Combustible Alcove Installation RequirementsRainier Minimum Clearance See Illustration belowWith Reduced Clearance Connector Mobile Home RequirementsMinimum Clearance Rainier See Illustration below Chimney Cap See the section Chimney T E T e r i o r C t o r y I l t I m n e yInterior or Exterior Masonry Chimney Clearance fireplaces Insert Installation ConsiderationsSurround Panels 28 to 144 not approved for zeroInsert Placement Requirements Insert Size Requirements see Illustration belowHearth Requirements Drafting Performance Leveling Bolt InstallationMasonry Fireplace Requirements Zero-Clearance Metal Fireplace RequirementsBlock-Off Plate Template Block-Off Plate InstallationInsert with Positive Connection Insert with Opening the Door Safety NoticeOperating Your Appliance Before Your First FireStarting a Fire Adjusting the Burn Rate Approximate Air Control SettingsAsh Removal Normal Operating Sounds Optional Blower OperationRe-Loading the Stove Overnight BurnSelecting Wood Hints for BurningTroubleshooting Remove Ash if necessary Daily Maintenance while stove is in useClean the Glass if necessary Maintaining Your ApplianceMonthly Maintenance while appliance is in use Door and Glass InspectionCreosote Formation and Need for Removal Firebrick and Baffle Inspection Yearly MaintenanceCleaning the Air Duct and Blower if applicable Touch Up PaintReplacing the Door Handle Door PartsReplacing the Glass Replacing the Door GasketFloor and Side Firebrick Removal & Replacement Firebox PartsTravis Industries 100-01140 060417 Baffle Removal & Replacement Air Tube Removal & ReplacementYears 6 & 7 Coverage Parts only Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 3 Through 5 Coverage Parts & LaborListing Label Freestanding InstallationOptional Equipment PedestalTravis Industries 100 080103 Top View Outside Air Installation for wood stoves onlyInstall the wire clip following the directions below Rear Blower Installation Part numberOutside Air Boot Installation Part number Z e Size on Insert w trim Required for face seal installations onlySurround Panels see s below Travis Industries 100-01140 051104Front Blower To Switch the Power Cord to the Left SideOptional Equipment 44Index